sensors/pwmconfig-raise-fan-threshold.patch

28 lines
1.0 KiB
Diff

From: Jean Delvare <jdelvare@suse.de>
Subject: pwmconfig: Further raise the fan threshold
References: boo#1181890
Upstream: not yet, submitted 2021-02-11 but upstream is dead
Modern 4-pin fans can have a minimum speed (PWM=0) which is still
relatively high. I've seen 4500 RPM fans lower their speed to only
3500 RPM, which is 77% of the maximum speed, above our current
detection threshold (3/4 or 75%). Increase the threshold to 5/6
(roughly 83%) to make sure such fans are handled properly.
Signed-off-by: Jean Delvare <jdelvare@suse.de>
---
prog/pwm/pwmconfig | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
--- lm-sensors.orig/prog/pwm/pwmconfig 2021-02-11 11:31:40.636126815 +0100
+++ lm-sensors/prog/pwm/pwmconfig 2021-02-11 15:30:12.831007617 +0100
@@ -455,7 +455,7 @@ do
OS=$(echo $SPEEDS | cut -d' ' -f$count)
S=$(echo $CURRENT_SPEEDS | cut -d' ' -f$count)
echo " $j ... speed was $OS now $S"
- let threshold=3*$OS/4
+ let threshold=5*$OS/6
if [ $S -lt $threshold ]
then
echo " It appears that fan $j"