xen/block-npiv-common.sh

278 lines
7.8 KiB
Bash

# Look for the NPIV vport with the WWPN
# $1 contains the WWPN (assumes it does not contain a leading "0x")
find_vhost()
{
unset vhost
# look in upstream locations
for fchost in /sys/class/fc_vports/* ; do
if test -e $fchost/port_name ; then
wwpn=`cat $fchost/port_name | sed -e s/^0x//`
if test $wwpn = $1 ; then
# Note: makes the assumption the vport will always have an scsi_host child
vhost=`ls -d $fchost/device/host*`
vhost=`basename $vhost`
return
fi
fi
done
# look in vendor-specific locations
# Emulex - just looks like another scsi_host - so look at fc_hosts...
for fchost in /sys/class/fc_host/* ; do
if test -e $fchost/port_name ; then
wwpn=`cat $fchost/port_name | sed -e s/^0x//`
if test $wwpn = $1 ; then
# Note: makes the assumption the vport will always have an scsi_host child
vhost=`basename $fchost`
return
fi
fi
done
}
# Create a NPIV vport with WWPN
# $1 contains the VPORT WWPN
# $2 may contain the VPORT WWNN
# (assumes no name contains a leading "0x")
create_vport()
{
wwpn=$1
wwnn=$2
if [ -z "$wwnn" ]; then
# auto generate wwnn, follow FluidLabUpdateForEmulex.pdf
# Novell specific identifier
# byte 6 = 0 indicates WWNN, = 1 indicates WWPN
wwnn=${wwpn:0:6}"0"${wwpn:7}
fi
# find a base adapter with npiv support that is on the right fabric
# Look via upstream interfaces
for fchost in /sys/class/fc_host/* ; do
if test -e $fchost/vport_create ; then
# is the link up, w/ NPIV support ?
pstate=`cat $fchost/port_state`
ptype=`cat $fchost/port_type | cut -c 1-5`
if [ $pstate = "Online" -a $ptype = "NPort" ] ; then
vmax=`cat $fchost/max_npiv_vports`
vinuse=`cat $fchost/npiv_vports_inuse`
avail=`expr $vmax - $vinuse`
if [ $avail -gt 0 ] ; then
# create the vport
echo $wwpn":"$wwnn > $fchost/vport_create
if [ $? -eq 0 ] ; then
return 0
fi
# failed - so we'll just look for the next adapter
fi
fi
fi
done
# Look in vendor-specific locations
# Emulex: interfaces mirror upstream, but are under adapter scsi_host
for shost in /sys/class/scsi_host/* ; do
if [ -e $shost/vport_create ] ; then
fchost=`ls -d $shost/device/fc_host*`
# is the link up, w/ NPIV support ?
if [ -e $fchost/port_state ] ; then
pstate=`cat $fchost/port_state`
ptype=`cat $fchost/port_type | cut -c 1-5`
if [ $pstate = "Online" -a $ptype = "NPort" ] ; then
vmax=`cat $shost/max_npiv_vports`
vinuse=`cat $shost/npiv_vports_inuse`
avail=`expr $vmax - $vinuse`
if [ $avail -gt 0 ] ; then
# create the vport
echo $wwpn":"$wwnn > $shost/vport_create
if [ $? -eq 0 ] ; then
return 0
fi
# failed - so we'll just look for the next adapter
fi
fi
fi
fi
done
# BFA are under adapter scsi_host
for shost in /sys/class/scsi_host/* ; do
if [ -e $shost/vport_create ] ; then
fchost=`ls -d $shost/device/fc_host/*`
# is the link up, w/ NPIV support ?
if [ -e $fchost/port_state ] ; then
pstate=`cat $fchost/port_state`
ptype=`cat $fchost/port_type | cut -c 1-5`
if [ $pstate = "Online" -a $ptype = "NPort" ] ; then
# create the vport
echo $wwpn":"$wwnn > $shost/vport_create
if [ $? -eq 0 ] ; then
return 0
fi
# failed - so we'll just look for the next adapter
fi
fi
fi
done
return 1
}
# Look for the LUN on the indicated scsi_host (which is an NPIV vport)
# $1 is the scsi_host name (normalized to simply the hostX name)
# $2 is the WWPN of the tgt port the lun is on
# Note: this implies we don't support a multipath'd lun, or we
# are explicitly identifying a "path"
# $3 is the LUN number of the scsi device
find_sdev()
{
unset dev
hostno=${1/*host/}
for sdev in /sys/class/scsi_device/${hostno}:*:$3 ; do
if test -e $sdev/device/../fc_trans*/target${hostno}*/port_name ; then
tgtwwpn=`cat $sdev/device/../fc_trans*/target${hostno}*/port_name | sed -e s/^0x//`
if test $tgtwwpn = $2 ; then
if test -e $sdev/device/block* ; then
dev=`ls $sdev/device/block*`
dev=${dev##*/}
return
fi
fi
fi
done
}
# Look for the NPIV vhost based on a scsi "sdX" name
# $1 is the "sdX" name
find_vhost_from_dev()
{
unset vhost
hostno=`readlink /sys/block/$1/device`
hostno=${hostno##*/}
hostno=${hostno%%:*}
if test -z "$hostno" ; then return; fi
vhost="host"$hostno
}
# We're about to terminate a vhost based on a scsi device
# Flush all nodes on that vhost as they are about to go away
# $1 is the vhost
flush_nodes_on_vhost()
{
if test ! -x /sbin/blockdev ; then return; fi
hostno=${1/*host/}
for sdev in /sys/class/scsi_device/${hostno}:* ; do
if test -e $sdev/device/block* ; then
dev=`ls $sdev/device/block*`
dev="/dev/"$dev
if test -n "$dev"; then
blockdev --flushbufs $dev
fi
fi
done
}
# Terminate a NPIV vhost
# $1 is vhost
delete_vhost()
{
# use upstream interface
for vport in /sys/class/fc_vports/* ; do
if test -e $vport/device/$1 ; then
if test -e $vport/vport_delete ; then
echo "1" > $vport/vport_delete
if test $? -ne 0 ; then exit 6; fi
sleep 4
return
fi
fi
done
# use vendor specific interface
# Emulex
if test -e /sys/class/fc_host/$1/device/../scsi_host*/lpfc_drvr_version ; then
shost=`ls -1d /sys/class/fc_host/$1/device/../scsi_host* | sed s/.*scsi_host://`
vportwwpn=`cat /sys/class/fc_host/$1/port_name | sed s/^0x//`
vportwwnn=`cat /sys/class/fc_host/$1/node_name | sed s/^0x//`
echo "$vportwwpn:$vportwwnn" > /sys/class/scsi_host/$shost/vport_delete
if test $? -ne 0 ; then exit 6; fi
sleep 4
return
fi
# Qlogic
if test -e /sys/class/fc_host/$1/device/../scsi_host*/driver_version ; then
shost=`ls -1d /sys/class/fc_host/$1/device/../scsi_host* | sed s/.*scsi_host://`
vportwwpn=`cat /sys/class/fc_host/$1/port_name | sed s/^0x//`
vportwwnn=`cat /sys/class/fc_host/$1/node_name | sed s/^0x//`
echo "$vportwwpn:$vportwwnn" > /sys/class/scsi_host/$shost/vport_delete
if test $? -ne 0 ; then exit 6; fi
sleep 4
return
fi
# BFA
if test -e /sys/class/fc_host/$1/device/../scsi_host/*/driver_name ; then
shost=`ls -1d /sys/class/fc_host/$1/device/../scsi_host/* | sed s#.*scsi_host/##`
vportwwpn=`cat /sys/class/fc_host/$1/port_name | sed s/^0x//`
vportwwnn=`cat /sys/class/fc_host/$1/node_name | sed s/^0x//`
echo "$vportwwpn:$vportwwnn" > /sys/class/scsi_host/$shost/vport_delete
if test $? -ne 0 ; then exit 6; fi
sleep 4
return
fi
exit 6
}
vport_status()
{
# Look via upstream interfaces
for fchost in /sys/class/fc_host/* ; do
if test -e $fchost/vport_create ; then
vport_status_display $fchost $fchost
fi
done
# Look in vendor-specific locations
# Emulex: interfaces mirror upstream, but are under adapter scsi_host
for shost in /sys/class/scsi_host/* ; do
if [ -e $shost/vport_create ] ; then
fchost=`ls -d $shost/device/fc_host*`
vport_status_display $fchost $shost
fi
done
return 0
}
vport_status_display()
{
echo
echo "fc_host: " $2
echo "port_state: " `cat $1/port_state`
echo "port_type: " `cat $1/port_type`
echo "fabric_name: " `cat $1/fabric_name`
echo "max_npiv_vports: " `cat $2/max_npiv_vports`
echo "npiv_vports_inuse: " `cat $2/npiv_vports_inuse`
echo "modeldesc: " `cat $2/modeldesc`
echo "speed: " `cat $1/speed`
return 0
}