Emit this when we're about to spawn or DBus activate a GAppInfo. This
allows lauchers to keep the appinfo associated with a startup id.
We use a GVariant to allow for future exansion of the supplied data.
When using g_desktop_app_info_launch_uris_as_manager the "launched"
signal allows to map a desktop-startup-id to a GAppInfo. Make this
possible for DBus activation too.
Since we don't have a PID there we pass a 0. Update the signal
description accordingly.
These should be implemented by loadable IO module libraries, but are not
callable in GLib itself.
Signed-off-by: Philip Withnall <pwithnall@endlessos.org>
Fixes: #2498
The function pointer casts silence the compiler and allow the code to
build (and even run in the typical case). However, when building with
control flow integrity checks, the runtime (rightfully) complains about
calling a function via a mismatched function pointer type.
In order to make xdgmime properly relocatable so that unit tests can use
it without it reading and modifying the user’s actual xdgmime files, and
without the need to call setenv() (and get tied up with thread safety
problems), add a xdg_mime_set_dirs() method to allow the dirs to be
overridden. They will still default to the values of $XDG_DATA_HOME and
$XDG_DATA_DIRS.
Signed-off-by: Philip Withnall <withnall@endlessm.com>
Allocate an empty cache object, check cache objects for being empty
before using them.
Otherwise the code will re-read cache every 5 seconds, as NULL cache
does not trigger the code that stores mtime, which makes the cache
file appear modified/unloaded permanently.
https://bugzilla.gnome.org/show_bug.cgi?id=735696
Since returning exactly one match has special significance, don't
give up matching before we've found at least 2 types. Also, make
sure that we don't return the same mime type more than once.
Bug 541236.
If an `InterfacesRemoved` signal is received for an object which doesn’t
exist in the local map of interfaces, don’t emit a warning.
This seems to happen in the real world (see #2401). Without a trace of
the D-Bus traffic it’s not possible to know exactly what situation is
causing this, but it seems possible that the peer could disappear and
its `notify::name-owner` signal could be processed before its
`InterfacesRemoved` signal, or something similar.
Signed-off-by: Philip Withnall <pwithnall@endlessos.org>
Fixes: #2401
Instead of calling xterm when it clearly does not exist and causes a silent error,
inform the user that the launch failed so they can take the right action.
Also added (transfer full) or (transfer none) annotations while I was at it.
This is the result of checking each `Returns:` line in these files. I’ve
only considered nullability and transferability, and not other (potentially
missing or incorrect) annotations.
Helps: #2227
If the first power-profile installed test fails (for example, because
xdg-desktop-portal isn’t available), correctly tear down the dbusmock
object, or it will cause setUp() to fail when the next test in the suite
is run.
Signed-off-by: Philip Withnall <pwithnall@endlessos.org>
Helps: #2481
When first creating the monitor, correctly set its property value to the
value from the portal, rather than waiting for the portal value to
change to set it.
Signed-off-by: Philip Withnall <pwithnall@endlessos.org>
Fixes: #2481
We were lucky that this worked in some cases (the test is racy), but we
should actually run the condition check each loop, rather than when the
function is called.
Spotted by Martin Pitt:
96a8c02d24 (r54773831)