dracut/0312-40network-Do-not-print-message-about-tmp-net.ibft0.c.patch
Thomas Renninger d9c684105c Accepting request 434686 from home:hreinecke:branches:Base:System
- 95resume: Do not resume on iSCSI devices (bsc#999663)
  *add 0310-95resume-Do-not-resume-on-iSCSI.patch
- 95iscsi: ip=ibft is deprecated (bsc#1004437)
  *add 0311-95iscsi-ip-ibft-is-deprecated.patch
- 40network: do not print warning about non-existing file
  (bsc#1004437)
  *add 0312-40network-Do-not-print-message-about-tmp-net.ibft0.c.patch

- 90dmraid: do not delete partitions (bsc#998860)
  *add 0309-90dmraid-do-not-delete-partitions.patch

- Give-persistent_policy-precedence-over-dev-mapper-names (bsc#908143)
  *add: 0502-persistent_device_policy_param_enhance.patch
- mdadm IMSM_NO_PLATFORM workaround for kdump (bsc#975404)
  *add: 0308-mdraid_add_IMSM_NO_PLATFORM_env.patch

OBS-URL: https://build.opensuse.org/request/show/434686
OBS-URL: https://build.opensuse.org/package/show/Base:System/dracut?expand=0&rev=268
2016-10-13 13:03:19 +00:00

41 lines
1.2 KiB
Diff

From cc2bdf6b3bf0fcaa6597ee652c024027da24b501 Mon Sep 17 00:00:00 2001
From: Hannes Reinecke <hare@suse.de>
Date: Thu, 13 Oct 2016 10:27:57 +0200
Subject: [PATCH 3/3] 40network: Do not print message about /tmp/net.ibft0.conf
not found
We need to check if the file /tmp/net.X.conf exists before trying
to read from it; not doing so will create a warning during boot.
References: bsc#1004437
Signed-off-by: Hannes Reinecke <hare@suse.com>
---
modules.d/40network/ifup.sh | 10 ++++++----
1 file changed, 6 insertions(+), 4 deletions(-)
diff --git a/modules.d/40network/ifup.sh b/modules.d/40network/ifup.sh
index a4515d1..a684cba 100755
--- a/modules.d/40network/ifup.sh
+++ b/modules.d/40network/ifup.sh
@@ -506,10 +506,12 @@ for p in $(getargs ip=); do
[ "$autoconf" = "ibft" ] && continue
# skip if same configuration appears twice
- while read line
- do
- [ "$line" = "$p" ] && continue 2
- done < /tmp/net.${netif}.conf
+ if [ -f /tmp/net.${netif}.conf ] ; then
+ while read line
+ do
+ [ "$line" = "$p" ] && continue 2
+ done < /tmp/net.${netif}.conf
+ fi
echo $p >> /tmp/net.${netif}.conf
--
2.6.6