- FreeIPMI 1.2.3 - 11/14/12
------------------------- Tools ------ o In ipmi-oem, support new Dell Poweredge R720 OEM commands extensions, including: - get-nic-selection-failover - set-nic-selection-failover - power-monitoring-over-interval - power-monitoring-interval-range - get-last-post-code o In ipmi-oem, update active-lom-status for Dell Poweredge R720. o In ipmi-oem, support new Dell Poweredge R720 get-system-info option 'cmc-info'. o In ipmi-oem, Dell get-system-info "slot-number" key changed to "blade-slot-info". Legacy option still supported. o In ipmi-sel, support Dell Poweredge R720 OEM SEL extensions. o In all tools, support nochecksumcheck workaround option. o In all daemons (ipmiseld, ipmidetectd, bmc-watchdog), check for syscall errors during daemon setup. Libraries --------- o In libfreeipmi, support Dell R720 OEM extension intepretations. o In libfreeipmi, libipmimonitoring, and libipmiconsole, support NO_CHECKSUM_CHECK workaround flag. o In libipmiconsole, IPMICONSOLE_DEBUG_FILE logs debug to files in current working directory and not /var/log. PID is also appended to debug files. OBS-URL: https://build.opensuse.org/package/show/systemsmanagement/freeipmi?expand=0&rev=16
This commit is contained in:
parent
b38fc64974
commit
c91e86fed3
@ -1,3 +0,0 @@
|
||||
version https://git-lfs.github.com/spec/v1
|
||||
oid sha256:34c6e74348496b232d335d5887f050be60ff79e8ef1149e1f69aba4620acc5ab
|
||||
size 2148119
|
3
freeipmi-1.2.3.tar.bz2
Normal file
3
freeipmi-1.2.3.tar.bz2
Normal file
@ -0,0 +1,3 @@
|
||||
version https://git-lfs.github.com/spec/v1
|
||||
oid sha256:853e0ed630124fa39391ac6e9d2c9f948a6c6319d5806b178135e6f01c44d888
|
||||
size 2164942
|
@ -1,3 +1,40 @@
|
||||
-------------------------------------------------------------------
|
||||
Thu Nov 15 08:59:44 UTC 2012 - kkaempf@suse.com
|
||||
|
||||
- FreeIPMI 1.2.3 - 11/14/12
|
||||
-------------------------
|
||||
Tools
|
||||
------
|
||||
o In ipmi-oem, support new Dell Poweredge R720 OEM commands extensions,
|
||||
including:
|
||||
- get-nic-selection-failover
|
||||
- set-nic-selection-failover
|
||||
- power-monitoring-over-interval
|
||||
- power-monitoring-interval-range
|
||||
- get-last-post-code
|
||||
o In ipmi-oem, update active-lom-status for Dell Poweredge R720.
|
||||
o In ipmi-oem, support new Dell Poweredge R720 get-system-info option
|
||||
'cmc-info'.
|
||||
o In ipmi-oem, Dell get-system-info "slot-number" key changed to
|
||||
"blade-slot-info". Legacy option still supported.
|
||||
o In ipmi-sel, support Dell Poweredge R720 OEM SEL extensions.
|
||||
o In all tools, support nochecksumcheck workaround option.
|
||||
o In all daemons (ipmiseld, ipmidetectd, bmc-watchdog), check for
|
||||
syscall errors during daemon setup.
|
||||
|
||||
Libraries
|
||||
---------
|
||||
o In libfreeipmi, support Dell R720 OEM extension intepretations.
|
||||
o In libfreeipmi, libipmimonitoring, and libipmiconsole, support
|
||||
NO_CHECKSUM_CHECK workaround flag.
|
||||
o In libipmiconsole, IPMICONSOLE_DEBUG_FILE logs debug to files in
|
||||
current working directory and not /var/log. PID is also appended
|
||||
to debug files.
|
||||
|
||||
Misc
|
||||
----
|
||||
o Various documentation updates and fixes.
|
||||
|
||||
-------------------------------------------------------------------
|
||||
Thu Oct 4 08:58:15 UTC 2012 - kkaempf@suse.com
|
||||
|
||||
|
@ -18,7 +18,7 @@
|
||||
|
||||
|
||||
%define name freeipmi
|
||||
%define version 1.2.2
|
||||
%define version 1.2.3
|
||||
%if %{?_with_debug:1}%{!?_with_debug:0}
|
||||
%define release 1.debug%{?dist}
|
||||
%else
|
||||
@ -35,7 +35,7 @@ Source: ftp://ftp.gnu.org/gnu/freeipmi/%{name}-%{version}.tar.bz2
|
||||
|
||||
Summary: FreeIPMI
|
||||
License: GPL-3.0+
|
||||
Group: Applications/System
|
||||
Group: System/Management
|
||||
BuildRequires: automake
|
||||
BuildRequires: libgcrypt-devel
|
||||
BuildRequires: libtool
|
||||
@ -68,7 +68,7 @@ header files and static libraries.
|
||||
|
||||
%package bmc-watchdog
|
||||
Summary: FreeIPMI BMC watchdog
|
||||
Group: Applications/System
|
||||
Group: System/Management
|
||||
%if 0%{?suse_version}
|
||||
Requires(pre): %fillup_prereq
|
||||
%endif
|
||||
@ -84,7 +84,7 @@ Provides a watchdog daemon for OS monitoring and recovery.
|
||||
|
||||
%package ipmidetectd
|
||||
Summary: IPMI node detection monitoring daemon
|
||||
Group: Applications/System
|
||||
Group: System/Management
|
||||
Requires: freeipmi = %{version}
|
||||
%if 0%{?fedora_version} || 0%{?centos_version} || 0%{?rhel_version} || 0%{?fedora} || 0%{?rhel}
|
||||
Requires(post): chkconfig
|
||||
@ -109,8 +109,13 @@ libtoolize --force --automake --copy
|
||||
autoconf
|
||||
automake --gnu --include-deps --copy --add-missing
|
||||
%endif
|
||||
%if 0%{?fedora_version} || 0%{?centos_version} || 0%{?rhel_version} || 0%{?fedora} || 0%{?rhel}
|
||||
%define docpath %{_docdir}/%{name}-%{version}
|
||||
%else
|
||||
%define docpath %{_docdir}/%{name}
|
||||
%endif
|
||||
%configure --program-prefix=%{?_program_prefix:%{_program_prefix}} \
|
||||
--docdir=%{_docdir}/%{name} \
|
||||
--docdir=%{docpath} \
|
||||
%{?_enable_debug} --disable-static
|
||||
CFLAGS="%{optflags}" make %{?_smp_mflags}
|
||||
|
||||
@ -128,7 +133,7 @@ mkdir -p %{buildroot}/%{_initddir}
|
||||
%if 0%{?suse_version}
|
||||
%makeinstall
|
||||
%else
|
||||
%makeinstall DESTDIR=%{buildroot}
|
||||
make install DESTDIR=%{buildroot}
|
||||
%endif
|
||||
|
||||
# Silent build check warning
|
||||
|
Loading…
Reference in New Issue
Block a user