Accepting request 1033048 from Base:System
OBS-URL: https://build.opensuse.org/request/show/1033048 OBS-URL: https://build.opensuse.org/package/show/openSUSE:Factory/nvme-cli?expand=0&rev=61
This commit is contained in:
commit
3d54ca2530
2
_service
2
_service
@ -4,7 +4,7 @@
|
||||
<param name="url">https://github.com/linux-nvme/nvme-cli.git</param>
|
||||
<param name="filename">nvme-cli</param>
|
||||
<param name="versionformat">@PARENT_TAG@</param>
|
||||
<param name="revision">v2.1.2</param>
|
||||
<param name="revision">v2.2.1</param>
|
||||
<param name="versionrewrite-pattern">v(.*)</param>
|
||||
<param name="changesgenerate">enable</param>
|
||||
</service>
|
||||
|
@ -1,6 +1,6 @@
|
||||
<servicedata>
|
||||
<service name="tar_scm">
|
||||
<param name="url">https://github.com/linux-nvme/nvme-cli.git</param>
|
||||
<param name="changesrevision">93dd92fefd36581fc795909ed4a1b07e23e92acc</param>
|
||||
<param name="changesrevision">aff7a09da61a555cea25c48b24224b6e45b905df</param>
|
||||
</service>
|
||||
</servicedata>
|
@ -1,3 +0,0 @@
|
||||
version https://git-lfs.github.com/spec/v1
|
||||
oid sha256:4842a9e3419886535cafce3870e380cff1017ae7aa163cf40bdddbe1fd7692aa
|
||||
size 6197773
|
3
nvme-cli-2.2.1.obscpio
Normal file
3
nvme-cli-2.2.1.obscpio
Normal file
@ -0,0 +1,3 @@
|
||||
version https://git-lfs.github.com/spec/v1
|
||||
oid sha256:303faf2ede22290f13b176829db1fa04c2402e540df73b5e3b8f835bfcb19e98
|
||||
size 6653965
|
@ -1,2 +0,0 @@
|
||||
addFilter("W: systemd-service-without-service_del_preun")
|
||||
addFilter("W: systemd-service-without-service_del_postun")
|
@ -1,3 +1,93 @@
|
||||
-------------------------------------------------------------------
|
||||
Wed Nov 02 17:10:58 UTC 2022 - Daniel Wagner <daniel.wagner@suse.com>
|
||||
|
||||
- Update to version 2.2.1:
|
||||
* Added parsing for Solidigm telemetry observable data.
|
||||
* add item ddr_ecc_err_cnt in smart-log-add
|
||||
* build: Drop dependency on libuuid
|
||||
* build: Fix endian check for cross build
|
||||
* build: Remove unused uuid.wrap file
|
||||
* build: Remove unusned uuid.h include
|
||||
* completions: Add show-topology tab completion
|
||||
* fabrics: Honor JSON config file in connect-all command
|
||||
* fabrics: Trigger auto connect if config.json exists
|
||||
* fabrics: fix 'persistent' handling during connect-all with JSON file
|
||||
* fabrics: nvme config --modify depends on -n and -t argument
|
||||
* fabrics: re-read the discovery log page when a discovery controller reconnected
|
||||
* json: Support uint64 types serialization for older json-c versions
|
||||
* nvme, plugins: fix __u64 -> unsigned long long assumptions
|
||||
* nvme-print: Add missing values in id-ctrl for JSON output
|
||||
* nvme-print: Handle NULL hostid in JSON output
|
||||
* nvme-print: Output 128bit values as uint128 type instead of double
|
||||
* nvme-print: Print fguid as a UUID
|
||||
* nvme-print: Use uint128 JSON function for media_units_written
|
||||
* nvme-print: decode MI status values
|
||||
* nvme-print: decode status types
|
||||
* nvme-print: fix wrong json key
|
||||
* nvme: Add helper function to parse 16-bit comma separated list
|
||||
* nvme: Add nvme_cmd wrapper for get_features
|
||||
* nvme: Add show-topology command
|
||||
* nvme: Add wrapper for Format NVM
|
||||
* nvme: Add wrapper for Sanitize NVM
|
||||
* nvme: Add wrappers for Get Log page helpers
|
||||
* nvme: Add wrappers for Identify controller lists
|
||||
* nvme: Add wrappers for NS attach/detach
|
||||
* nvme: Add wrappers for NS management functions
|
||||
* nvme: Add wrappers for basic NS identify
|
||||
* nvme: Add wrappers for firmware commands
|
||||
* nvme: Fix set feature command to get feature identifier 0Dh length as zero
|
||||
* nvme: Introduce a union in struct nvme_dev for different transport types
|
||||
* nvme: Introduce nvme_cli_ wrappers, wrap identify and identify_ctrl
|
||||
* nvme: Make static nvme_dev private to open_dev(), use locals elsewhere
|
||||
* nvme: Masks SSTAT in sanize-log output
|
||||
* nvme: Remove static nvme_dev, allocate on open instead
|
||||
* nvme: Use correct print format specifier for sizeof arguments
|
||||
* nvme: Use local struct nvme_dev for show_registers & map_registers
|
||||
* nvme: check if cfg.metadata is NULL before passing it to strlen()
|
||||
* nvme: use helpers for checking status types
|
||||
* plugins/innogrit: Include timer.h
|
||||
* plugins/innogrit: add smart items for smart-log-add
|
||||
* plugins/micron-nvme: Use correct print format specifier for sizeof arguments
|
||||
* plugins/ocp: Include timer.h
|
||||
* plugins/ocp: Output 128bit values as uint128 type instead of double
|
||||
* plugins/ocp: pass struct nvme_dev to internal functions
|
||||
* plugins/seagate: Add support for OCP
|
||||
* plugins/toshiba: pass struct nvme_dev rather than fd + name
|
||||
* plugins/virtium: Output 128bit values as uint128 type instead of double
|
||||
* plugins/wdc: Add support for SN660 drive
|
||||
* plugins/wdc: Add type case for feature id
|
||||
* plugins/wdc: Output 128bit values as uint128 type instead of double
|
||||
* plugins/wdc: pass a struct nvme_dev around rather than a fd
|
||||
* plugins/wdc: pass struct nvme_dev rather than using global nvme_dev
|
||||
* plugins/ytmc: pass struct nvme_dev rather than fd + name
|
||||
* plugins: Use PRIu64 format specifier for 64bit types
|
||||
* print: Add Controller Ready Timeout Exceeded HW error code
|
||||
* solidgm: fix initialization warning
|
||||
* solidigm: Added parsing for telemetry customer screenable data
|
||||
* solidigm: Fix printf format for size_t variable
|
||||
* solidigm: Updated Telemetry parsing code to MIT license.
|
||||
* subprojects/libnvme: update for MI admin command coverage
|
||||
* tests: Update license to GPL-2.0-or-later
|
||||
* tree: Add NVMe-MI support
|
||||
* tree: Add dev_fd() helper
|
||||
* tree: Change nvme_dev from global to static
|
||||
* tree: Combine NVMe file descriptor into struct nvme_dev
|
||||
* tree: Move global device info to a single struct
|
||||
* tree: fail on non-negative return values from parse_and_open
|
||||
* udev: Add HOST_IFACE to udev rule
|
||||
* util/json.h: Add json_object_get_uint64 fallback implementation
|
||||
* util/json: Add 128 bit JSON helpers
|
||||
* util/types: Add 128 bit conversion helpers
|
||||
* util: Fix le128_to_cpu on big-endian
|
||||
* util: Fix le128_to_cpu on little-endian
|
||||
* util: Move common type conversion helpers into util section
|
||||
* utils/json: Add json_object_new_uint64 for json-c < 0.14
|
||||
* utils: Fix uint128_t usage
|
||||
* wdc: OCP Log page updates and fixes
|
||||
* zns.c: report zones should be started after retrieved zone
|
||||
- Handle suse-missing-rclink lint warnings by providing the symlinks
|
||||
- Drop rpmlintrc as it is not needed anymore
|
||||
|
||||
-------------------------------------------------------------------
|
||||
Wed Sep 21 08:32:38 UTC 2022 - Daniel Wagner <daniel.wagner@suse.com>
|
||||
|
||||
|
@ -1,4 +1,4 @@
|
||||
name: nvme-cli
|
||||
version: 2.1.2
|
||||
mtime: 1660223255
|
||||
commit: 93dd92fefd36581fc795909ed4a1b07e23e92acc
|
||||
version: 2.2.1
|
||||
mtime: 1667403857
|
||||
commit: aff7a09da61a555cea25c48b24224b6e45b905df
|
||||
|
@ -17,14 +17,13 @@
|
||||
|
||||
|
||||
Name: nvme-cli
|
||||
Version: 2.1.2
|
||||
Version: 2.2.1
|
||||
Release: 0
|
||||
Summary: NVM Express user space tools
|
||||
License: GPL-2.0-only
|
||||
Group: Hardware/Other
|
||||
URL: https://github.com/linux-nvme/nvme-cli/
|
||||
Source0: nvme-cli-%{version}.tar.gz
|
||||
Source1: nvme-cli-rpmlintrc
|
||||
# downstream patches
|
||||
Patch100: 0100-harden_nvmf-connect@.service.patch
|
||||
BuildRequires: gcc
|
||||
@ -102,6 +101,12 @@ rm %{buildroot}%{_sysconfdir}/dracut/dracut.conf.d/70-nvmf-autoconnect.conf
|
||||
# for subpackage nvme-cli-regress-script:
|
||||
install -m 744 -D regress %{buildroot}%{_sbindir}/nvme-regress
|
||||
|
||||
mkdir -p %{buildroot}%{_sbindir}
|
||||
pushd %{buildroot}%{_sbindir}
|
||||
ln -s service rcnvmefc-boot-connections
|
||||
ln -s service rcnvmf-autoconnect
|
||||
popd
|
||||
|
||||
%define services nvmefc-boot-connections.service nvmf-connect.target nvmf-autoconnect.service
|
||||
|
||||
%pre
|
||||
@ -113,7 +118,7 @@ if [ ! -s %{_sysconfdir}/nvme/hostnqn ]; then
|
||||
%{_sbindir}/nvme gen-hostnqn > %{_sysconfdir}/nvme/hostnqn
|
||||
fi
|
||||
if [ ! -s %{_sysconfdir}/nvme/hostid ]; then
|
||||
%{_bindir}/uuidgen > %{_sysconfdir}/nvme/hostid
|
||||
sed -nr 's/.*:uuid:(.*?)$/\1/p' %{_sysconfdir}/nvme/hostnqn > %{_sysconfdir}/nvme/hostid
|
||||
fi
|
||||
%service_add_post %{services} nvmf-connect@.service
|
||||
|
||||
@ -137,6 +142,8 @@ fi
|
||||
%license LICENSE
|
||||
%doc README.md
|
||||
%{_sbindir}/nvme
|
||||
%{_sbindir}/rcnvmefc-boot-connections
|
||||
%{_sbindir}/rcnvmf-autoconnect
|
||||
%{_mandir}/man1/nvme*.1*%{?ext_man}
|
||||
%{_udevrulesdir}/70-nvmf-autoconnect.rules
|
||||
%{_udevrulesdir}/71-nvmf-iopolicy-netapp.rules
|
||||
|
Loading…
Reference in New Issue
Block a user