899e757986
- framework.patch added to fix build error w framework 1.12.10 - version 3.3 * OrthancWSIDicomizer: - New option "--encoding" to specify the specific character set of DICOM instances - Placeholder tags are now automatically inserted when the "--dataset" option provides incomplete data, ensuring the generated DICOM instances remain valid - The version of the DICOM-izer is available in DICOM tag "SoftwareVersions" - ImagedVolumeWidth and ImagedVolumeHeight are swapped with respect to releases <= 3.2: https://discourse.orthanc-server.org/t/5912 * Viewer plugin: - Added rotation button in the viewer - The viewer displays a label if the "description" GET parameter is provided - Upgraded to OpenLayers 10.6.1 - remove libboost_system-devel for TW (removed in boost 1.89) - version 3.2 * Support windowing when rendering grayscale images using on-the-fly deep zoom * Added tolerance to imaged volume width/height by looking only at the finest level * Added support for more transfer syntaxes in the Web viewer plugin, including JPEG-LS * Added support for JPEG-LS in OrthancWSIDicomizer with argument "--compression=jpeg-ls" * Fix photometric interpretation of JPEG2000 images generated by OrthancWSIDicomizer (now set to RGB instead of YBR_FULL_422) - version 3.1 * Upgraded to OpenLayers 10.4.0 (was previously 3.19.0) * The viewer now displays the scale if imaged volume size is available in DICOM * Fix handling of "Image Type" in the viewer for compatibility with other vendors * OrthancWSIDicomizer does not fill anymore the imaged volume width/height tags if no information is available * OrthancWSIDicomizer detects imaged volume size for Aperio files without OpenSlide - version 3.0 * Minimum SDK version: 1.7.0 * On-the-fly creation of pyramids from frames of DICOM instances - Version 2.1 * Support of sparse encoding of tiles in OpenSlide (notably for MIRAX format) * OrthancWSIDicomizer supports plain TIFF, besides hierarchical TIFF * New option: "--force-openslide" to force the use of OpenSlide on TIFF-like files * New option: "--padding" to control deep zoom of plain PNG/JPEG/TIFF images over IIIF * Added support for DICOM tag "Recommended Absent Pixel CIELab" (0048,0015) * Force version of Mirador to 3.3.0 * In the IIIF manifest, reverse the order of the "sizes" field, which seems to fix compatibility with Mirador v4.0.0-alpha
Axel Braun2025-12-13 11:21:47 +00:00
a570a87f50
- framework.diff added to fix build error w framework 1.12.10
Axel Braun2025-12-11 21:57:08 +00:00
96a101adfc
new attempt - some files missing (why?)
Axel Braun2025-11-09 21:55:58 +00:00
9c9d9c9e07
- version 3.3 * OrthancWSIDicomizer: - New option "--encoding" to specify the specific character set of DICOM instances - Placeholder tags are now automatically inserted when the "--dataset" option provides incomplete data, ensuring the generated DICOM instances remain valid - The version of the DICOM-izer is available in DICOM tag "SoftwareVersions" - ImagedVolumeWidth and ImagedVolumeHeight are swapped with respect to releases <= 3.2: https://discourse.orthanc-server.org/t/5912 * Viewer plugin: - Added rotation button in the viewer - The viewer displays a label if the "description" GET parameter is provided - Upgraded to OpenLayers 10.6.1
Axel Braun2025-11-09 21:51:54 +00:00
aac10ad61b
Accepting request 1304037 from graphics
Ana Guerrero2025-09-11 12:41:51 +00:00
041f9f5b6f
- version 3.2 * Support windowing when rendering grayscale images using on-the-fly deep zoom * Added tolerance to imaged volume width/height by looking only at the finest level * Added support for more transfer syntaxes in the Web viewer plugin, including JPEG-LS * Added support for JPEG-LS in OrthancWSIDicomizer with argument "--compression=jpeg-ls" * Fix photometric interpretation of JPEG2000 images generated by OrthancWSIDicomizer (now set to RGB instead of YBR_FULL_422)
Axel Braun2025-04-10 17:07:02 +00:00
c55f68c67d
Accepting request 1254808 from graphics
Ana Guerrero2025-03-21 19:22:05 +00:00
de5866e889
- version 3.1 * Upgraded to OpenLayers 10.4.0 (was previously 3.19.0) * The viewer now displays the scale if imaged volume size is available in DICOM * Fix handling of "Image Type" in the viewer for compatibility with other vendors * OrthancWSIDicomizer does not fill anymore the imaged volume width/height tags if no information is available * OrthancWSIDicomizer detects imaged volume size for Aperio files without OpenSlide
Axel Braun2025-03-20 18:00:25 +00:00
c87d75a637
Accepting request 1233001 from graphics
Ana Guerrero2024-12-22 17:04:57 +00:00
d4fcb4ddcb
- Version 2.1 * Support of sparse encoding of tiles in OpenSlide (notably for MIRAX format) * OrthancWSIDicomizer supports plain TIFF, besides hierarchical TIFF * New option: "--force-openslide" to force the use of OpenSlide on TIFF-like files * New option: "--padding" to control deep zoom of plain PNG/JPEG/TIFF images over IIIF * Added support for DICOM tag "Recommended Absent Pixel CIELab" (0048,0015) * Force version of Mirador to 3.3.0 * In the IIIF manifest, reverse the order of the "sizes" field, which seems to fix compatibility with Mirador v4.0.0-alpha
Axel Braun2024-10-19 07:17:32 +00:00