qemu/virtiofsd-optionally-return-inode-pointe.patch
Bruce Rogers 86ffd40d11 Accepting request 882222 from home:bfrogers:branches:Virtualization
- Switch method of splitting off hw-s390x-virtio-gpu-ccw.so as a
  module to what was accepted upstream (bsc#1181103)
* Patches dropped:
  hw-s390x-modularize-virtio-gpu-ccw.patch
* Patches added:
  s390x-add-have_virtio_ccw.patch
  s390x-modularize-virtio-gpu-ccw.patch
  s390x-move-S390_ADAPTER_SUPPRESSIBLE.patch
- Fix OOB access in sdhci interface (CVE-2020-17380, bsc#1175144,
  CVE-2020-25085, bsc#1176681, CVE-2021-3409, bsc#1182282)
  hw-sd-sd-Actually-perform-the-erase-oper.patch
  hw-sd-sd-Fix-build-error-when-DEBUG_SD-i.patch
  hw-sd-sdhci-Correctly-set-the-controller.patch
  hw-sd-sdhci-Don-t-transfer-any-data-when.patch
  hw-sd-sdhci-Don-t-write-to-SDHC_SYSAD-re.patch
  hw-sd-sdhci-Limit-block-size-only-when-S.patch
  hw-sd-sdhci-Reset-the-data-pointer-of-s-.patch
  hw-sd-sd-Move-the-sd_block_-read-write-a.patch
  hw-sd-sd-Skip-write-protect-groups-check.patch
- Fix potential privilege escalation in virtiofsd tool
  (CVE-2021-20263, bsc#1183373)
  tools-virtiofsd-Replace-the-word-whiteli.patch
  viriofsd-Add-support-for-FUSE_HANDLE_KIL.patch
  virtiofsd-extract-lo_do_open-from-lo_ope.patch
  virtiofsd-optionally-return-inode-pointe.patch
  virtiofsd-prevent-opening-of-special-fil.patch
  virtiofs-drop-remapped-security.capabili.patch
  virtiofsd-Save-error-code-early-at-the-f.patch
- Fix OOB access (stack overflow) in rtl8139 NIC emulation
  (CVE-2021-3416, bsc#1182968)
  net-introduce-qemu_receive_packet.patch
  rtl8139-switch-to-use-qemu_receive_packe.patch
- Fix OOB access (stack overflow) in other NIC emulations
  (CVE-2021-3416)
  cadence_gem-switch-to-use-qemu_receive_p.patch
  dp8393x-switch-to-use-qemu_receive_packe.patch
  e1000-switch-to-use-qemu_receive_packet-.patch
  lan9118-switch-to-use-qemu_receive_packe.patch
  msf2-mac-switch-to-use-qemu_receive_pack.patch
  pcnet-switch-to-use-qemu_receive_packet-.patch
  sungem-switch-to-use-qemu_receive_packet.patch
  tx_pkt-switch-to-use-qemu_receive_packet.patch
- Fix heap overflow in MSIx emulation (CVE-2020-27821, bsc#1179686)
  memory-clamp-cached-translation-in-case-.patch
- Include upstream patches designated as stable material and
  reviewed for applicability to include here
  hw-arm-virt-Disable-pl011-clock-migratio.patch
  xen-block-Fix-removal-of-backend-instanc.patch
- Fix package scripts to not use hard coded paths for temporary
  working directories and log files (bsc#1182425)

OBS-URL: https://build.opensuse.org/request/show/882222
OBS-URL: https://build.opensuse.org/package/show/Virtualization/qemu?expand=0&rev=632
2021-03-30 20:27:28 +00:00

109 lines
3.9 KiB
Diff

From: Stefan Hajnoczi <stefanha@redhat.com>
Date: Thu, 4 Feb 2021 15:02:07 +0000
Subject: virtiofsd: optionally return inode pointer from lo_do_lookup()
Git-commit: 22d2ece71e533310da31f2857ebc4a00d91968b3
References: bsc#1183373, CVE-2021-20263
lo_do_lookup() finds an existing inode or allocates a new one. It
increments nlookup so that the inode stays alive until the client
releases it.
Existing callers don't need the struct lo_inode so the function doesn't
return it. Extend the function to optionally return the inode. The next
commit will need it.
Signed-off-by: Stefan Hajnoczi <stefanha@redhat.com>
Reviewed-by: Greg Kurz <groug@kaod.org>
Message-Id: <20210204150208.367837-3-stefanha@redhat.com>
Signed-off-by: Dr. David Alan Gilbert <dgilbert@redhat.com>
Signed-off-by: Bruce Rogers <brogers@suse.com>
---
tools/virtiofsd/passthrough_ll.c | 29 +++++++++++++++++++++--------
1 file changed, 21 insertions(+), 8 deletions(-)
diff --git a/tools/virtiofsd/passthrough_ll.c b/tools/virtiofsd/passthrough_ll.c
index 218e20e9d7901f22e26ef8dc56c2..2bd050b6202e41476dc1cdce811a 100644
--- a/tools/virtiofsd/passthrough_ll.c
+++ b/tools/virtiofsd/passthrough_ll.c
@@ -843,11 +843,13 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,
}
/*
- * Increments nlookup and caller must release refcount using
- * lo_inode_put(&parent).
+ * Increments nlookup on the inode on success. unref_inode_lolocked() must be
+ * called eventually to decrement nlookup again. If inodep is non-NULL, the
+ * inode pointer is stored and the caller must call lo_inode_put().
*/
static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
- struct fuse_entry_param *e)
+ struct fuse_entry_param *e,
+ struct lo_inode **inodep)
{
int newfd;
int res;
@@ -857,6 +859,10 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
struct lo_inode *inode = NULL;
struct lo_inode *dir = lo_inode(req, parent);
+ if (inodep) {
+ *inodep = NULL;
+ }
+
/*
* name_to_handle_at() and open_by_handle_at() can reach here with fuse
* mount point in guest, but we don't have its inode info in the
@@ -924,7 +930,14 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
pthread_mutex_unlock(&lo->mutex);
}
e->ino = inode->fuse_ino;
- lo_inode_put(lo, &inode);
+
+ /* Transfer ownership of inode pointer to caller or drop it */
+ if (inodep) {
+ *inodep = inode;
+ } else {
+ lo_inode_put(lo, &inode);
+ }
+
lo_inode_put(lo, &dir);
fuse_log(FUSE_LOG_DEBUG, " %lli/%s -> %lli\n", (unsigned long long)parent,
@@ -959,7 +972,7 @@ static void lo_lookup(fuse_req_t req, fuse_ino_t parent, const char *name)
return;
}
- err = lo_do_lookup(req, parent, name, &e);
+ err = lo_do_lookup(req, parent, name, &e, NULL);
if (err) {
fuse_reply_err(req, err);
} else {
@@ -1067,7 +1080,7 @@ static void lo_mknod_symlink(fuse_req_t req, fuse_ino_t parent,
goto out;
}
- saverr = lo_do_lookup(req, parent, name, &e);
+ saverr = lo_do_lookup(req, parent, name, &e, NULL);
if (saverr) {
goto out;
}
@@ -1544,7 +1557,7 @@ static void lo_do_readdir(fuse_req_t req, fuse_ino_t ino, size_t size,
if (plus) {
if (!is_dot_or_dotdot(name)) {
- err = lo_do_lookup(req, ino, name, &e);
+ err = lo_do_lookup(req, ino, name, &e, NULL);
if (err) {
goto error;
}
@@ -1742,7 +1755,7 @@ static void lo_create(fuse_req_t req, fuse_ino_t parent, const char *name,
}
fi->fh = fh;
- err = lo_do_lookup(req, parent, name, &e);
+ err = lo_do_lookup(req, parent, name, &e, NULL);
}
if (lo->cache == CACHE_NONE) {
fi->direct_io = 1;