2008-04-12 21:21:14 +02:00
|
|
|
#! /bin/bash
|
|
|
|
#
|
|
|
|
# Johannes Meixner <jsmeix@suse.de>, 2008
|
|
|
|
|
|
|
|
#set -x
|
|
|
|
|
|
|
|
export PATH="/sbin:/usr/sbin:/usr/bin:/bin"
|
|
|
|
export LC_ALL="POSIX"
|
|
|
|
export LANG="POSIX"
|
|
|
|
umask 022
|
|
|
|
|
|
|
|
MY_NAME=${0##*/}
|
|
|
|
|
|
|
|
# Input:
|
|
|
|
|
|
|
|
# Create a temporary file:
|
|
|
|
TMP_DATA=$(mktemp -u /tmp/$MY_NAME.XXXXXX) || { echo "Error: Failed to make a temporary file /tmp/$MY_NAME.XXXXXX" 1>&2 ; exit 1 ; }
|
|
|
|
|
|
|
|
# Get the raw data:
|
|
|
|
egrep '^\[|^model[1-9]*|^scan-type|^usb-pid' | sed -e 's/^\[\(.*\)\]$/class=\1/' -e 's/ /_/g' -e 's/=/ /' >$TMP_DATA
|
|
|
|
|
|
|
|
# Output:
|
|
|
|
|
|
|
|
# Output header:
|
|
|
|
echo ':backend "hpaio"'
|
2009-09-21 21:28:38 +02:00
|
|
|
echo ':version "3.9.8"'
|
|
|
|
echo ':url "http://hplipopensource.com"'
|
2008-04-12 21:21:14 +02:00
|
|
|
echo ':comment "This backend is not included in SANE because it is included in the HPLIP software."'
|
|
|
|
echo ':devicetype :scanner'
|
|
|
|
echo ':mfg "Hewlett-Packard"'
|
|
|
|
echo ':url "http://www.hp.com/united-states/consumer/gateway/printing_multifunction.html"'
|
|
|
|
echo
|
|
|
|
# Add a generic entry (the "Any" with capital 'A' lets it appear at the top of YaST's sorted list):
|
|
|
|
# This USB ID ("0x03f0" "0x0000") is used as fallback by the YaST scanner autodetection
|
|
|
|
# via /usr/lib/YaST2/bin/autodetect_scanners which calls "hp-probe -busb -escan"
|
|
|
|
# because hp-probe does not show the USB ID. With this USB ID the generic entry matches
|
|
|
|
# to any autodetected HPLIP USB all-in-one device (the "-escan" excludes plain printers)
|
|
|
|
# so that the usually right driver (hpaio) can be preselected by YaST.
|
|
|
|
# Nevertheless, to be on the safe side, the support status is set to "untested".
|
|
|
|
echo ':model "Any all-in-one device"'
|
|
|
|
echo ':usbid "0x03f0" "0x0000"'
|
|
|
|
echo ':status :untested'
|
|
|
|
echo ':comment "fallback entry for HP all-in-one devices"'
|
|
|
|
echo
|
|
|
|
|
Accepting request 949860 from home:StefanBruens:branches:graphics
- Upgraded to sane-backends version 1.1.1
* Backends
+ epson2: Fixed support for many scanners that don't support
focus command.
+ epson2: Improve reliability of long scans.
+ epsonds: Implemented support for the following Epson scanners:
- DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
- ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
ES-60WW, ES-65WR,
- ET-2700 Series, ET-2710 Series, ET-2810 Series,
ET-M2140 Series, ET-M3140 Series,
- EW-052A Series,
- FF-680W,
- L3150 Series, L3200 Series, L3210 Series, L3250 Series,
L4150 Series,
- M2140 Series, M3140 Series,
- RR-60, RR-600W, RR-70W,
- XP-2100 Series, XP-2150 Series
+ epson2: Marked XP-452 455 series as supported in
documentation
+ escl: Fixed scanning problems on certain scanners due to
incorrect URL being used (#479)
+ escl: Fixed support for different resolutions when using
JPEG format
+ escl: Fixed handling of ipp-usb redirects to localhost
which previously caused certain scanners to be always
reported as busy
+ escl: Added support for Brother DCP-J772DW and Epson
ET-2750 scanners
+ escl: Marked the following scanners as supported in
documentation:
- Canon PIXMA G4511
- Canon PIXMA TR4550 Series
- Canon PIXMA TR4551 Series
- Epson ET-6100
+ escl: Implemented support for disabling PDF output on
scanners where it's broken (#510)
+ escl: Implemented support for Canon PIXME TR4520 and
TR7500 scanners
+ genesys: Improved scan quality on Canon LiDE 35/40/50/60
by using brighter LED illumination
+ genesys: Fixed control of contrast and brigthness on certain
scanners (#271)
+ genesys: Fixed crashes when handling slightly unexpected
conditions (#464)
+ genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
+ genesys: Fixed button support on HP ScanJet G4010
+ genesys: Fixed compilation on gcc-4.8
+ genesys: Fixed incorrect LED exposure calculation leading to
wrong color balance on certain resolutions on gl841 scanners
+ genesys: Improved gray scan quality on Canon LiDE 110, 120,
210, 220 (#106, #52)
+ genesys: Fixed issue of motor becoming stuck at certain
resolutions on Canon LiDE 50 and possibly other gl841
scanners (#357)
+ genesys: Fixed periodic black lines in gray scans on Canon
LiDE 80
+ genesys: Removed support for broken 75 and 100 dpi hardware
resolutions to fix preview scans (#383). These resolutions
did not have any benefit compared to next smallest 150 dpi
resolution
+ genesys: Add support for running in embedded environments
that don't support threads
+ genesys: Fixed gray scans to use white color for illumination
instead of red on Canon LiDE 35/40/50/60 and potentially
other gl841 scanners. Old behavior can be restored via the
color filter setting to select specific color component for
the gray scan
+ genesys: The genesys backend is now distributed under GPL v2
or later license. Previously there existed an exception that
allowed additional uses of the backend
+ gt68xx: Fixed several memory issues that can potentially lead
to crashes or increased memory use
+ hp4200: Fixed crash when using HP ScanJet 4200C (#454)
+ microtek: Fixed support for embedded platforms using uclibc
+ pieusb: Implemented support for Reflecta RPS 10M scanner
+ pieusb: Fixed support for automatically advancing slides on
DigitDia 4000
+ pixma: Fixed compliation with NDEBUG macro defined
+ pixma: Marked Canon PIXMA G4511 as supported in documentation
+ scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
as supported
* Frontends
+ Improved documentation of scanimage concerning options
provided by backends
+ scanimage: Improved help to specify which options are
advanced
+ scanimage: Implemented support for PDF output format
- Cleanup create_hpaio.desc_from_models.dat:
* Remove scanners unsupported by hplip (scan-type < 0)
* Simplify and significantly speed it up
OBS-URL: https://build.opensuse.org/request/show/949860
OBS-URL: https://build.opensuse.org/package/show/graphics/sane-backends?expand=0&rev=106
2022-01-31 14:34:31 +01:00
|
|
|
# Function to normalize model names:
|
|
|
|
Normalize()
|
|
|
|
{ MODELS=$( echo $MODELS | sed -e 's/hp_//ig' -e 's/Aii-in-One/all-in-one/ig' )
|
2008-04-12 21:21:14 +02:00
|
|
|
for w in LaserJet Mopier DeskJet Business Inkjet Officejet Photosmart PSC Printer Scanner Copier DJ CP CM MFP Apollo series Color all-in-one
|
Accepting request 949860 from home:StefanBruens:branches:graphics
- Upgraded to sane-backends version 1.1.1
* Backends
+ epson2: Fixed support for many scanners that don't support
focus command.
+ epson2: Improve reliability of long scans.
+ epsonds: Implemented support for the following Epson scanners:
- DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
- ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
ES-60WW, ES-65WR,
- ET-2700 Series, ET-2710 Series, ET-2810 Series,
ET-M2140 Series, ET-M3140 Series,
- EW-052A Series,
- FF-680W,
- L3150 Series, L3200 Series, L3210 Series, L3250 Series,
L4150 Series,
- M2140 Series, M3140 Series,
- RR-60, RR-600W, RR-70W,
- XP-2100 Series, XP-2150 Series
+ epson2: Marked XP-452 455 series as supported in
documentation
+ escl: Fixed scanning problems on certain scanners due to
incorrect URL being used (#479)
+ escl: Fixed support for different resolutions when using
JPEG format
+ escl: Fixed handling of ipp-usb redirects to localhost
which previously caused certain scanners to be always
reported as busy
+ escl: Added support for Brother DCP-J772DW and Epson
ET-2750 scanners
+ escl: Marked the following scanners as supported in
documentation:
- Canon PIXMA G4511
- Canon PIXMA TR4550 Series
- Canon PIXMA TR4551 Series
- Epson ET-6100
+ escl: Implemented support for disabling PDF output on
scanners where it's broken (#510)
+ escl: Implemented support for Canon PIXME TR4520 and
TR7500 scanners
+ genesys: Improved scan quality on Canon LiDE 35/40/50/60
by using brighter LED illumination
+ genesys: Fixed control of contrast and brigthness on certain
scanners (#271)
+ genesys: Fixed crashes when handling slightly unexpected
conditions (#464)
+ genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
+ genesys: Fixed button support on HP ScanJet G4010
+ genesys: Fixed compilation on gcc-4.8
+ genesys: Fixed incorrect LED exposure calculation leading to
wrong color balance on certain resolutions on gl841 scanners
+ genesys: Improved gray scan quality on Canon LiDE 110, 120,
210, 220 (#106, #52)
+ genesys: Fixed issue of motor becoming stuck at certain
resolutions on Canon LiDE 50 and possibly other gl841
scanners (#357)
+ genesys: Fixed periodic black lines in gray scans on Canon
LiDE 80
+ genesys: Removed support for broken 75 and 100 dpi hardware
resolutions to fix preview scans (#383). These resolutions
did not have any benefit compared to next smallest 150 dpi
resolution
+ genesys: Add support for running in embedded environments
that don't support threads
+ genesys: Fixed gray scans to use white color for illumination
instead of red on Canon LiDE 35/40/50/60 and potentially
other gl841 scanners. Old behavior can be restored via the
color filter setting to select specific color component for
the gray scan
+ genesys: The genesys backend is now distributed under GPL v2
or later license. Previously there existed an exception that
allowed additional uses of the backend
+ gt68xx: Fixed several memory issues that can potentially lead
to crashes or increased memory use
+ hp4200: Fixed crash when using HP ScanJet 4200C (#454)
+ microtek: Fixed support for embedded platforms using uclibc
+ pieusb: Implemented support for Reflecta RPS 10M scanner
+ pieusb: Fixed support for automatically advancing slides on
DigitDia 4000
+ pixma: Fixed compliation with NDEBUG macro defined
+ pixma: Marked Canon PIXMA G4511 as supported in documentation
+ scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
as supported
* Frontends
+ Improved documentation of scanimage concerning options
provided by backends
+ scanimage: Improved help to specify which options are
advanced
+ scanimage: Implemented support for PDF output format
- Cleanup create_hpaio.desc_from_models.dat:
* Remove scanners unsupported by hplip (scan-type < 0)
* Simplify and significantly speed it up
OBS-URL: https://build.opensuse.org/request/show/949860
OBS-URL: https://build.opensuse.org/package/show/graphics/sane-backends?expand=0&rev=106
2022-01-31 14:34:31 +01:00
|
|
|
do MODELS=$( echo $MODELS | sed -e "s/$w/$w/ig" )
|
2008-04-12 21:21:14 +02:00
|
|
|
done
|
|
|
|
}
|
|
|
|
|
|
|
|
# Function to output one model entry:
|
|
|
|
Output()
|
Accepting request 949860 from home:StefanBruens:branches:graphics
- Upgraded to sane-backends version 1.1.1
* Backends
+ epson2: Fixed support for many scanners that don't support
focus command.
+ epson2: Improve reliability of long scans.
+ epsonds: Implemented support for the following Epson scanners:
- DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
- ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
ES-60WW, ES-65WR,
- ET-2700 Series, ET-2710 Series, ET-2810 Series,
ET-M2140 Series, ET-M3140 Series,
- EW-052A Series,
- FF-680W,
- L3150 Series, L3200 Series, L3210 Series, L3250 Series,
L4150 Series,
- M2140 Series, M3140 Series,
- RR-60, RR-600W, RR-70W,
- XP-2100 Series, XP-2150 Series
+ epson2: Marked XP-452 455 series as supported in
documentation
+ escl: Fixed scanning problems on certain scanners due to
incorrect URL being used (#479)
+ escl: Fixed support for different resolutions when using
JPEG format
+ escl: Fixed handling of ipp-usb redirects to localhost
which previously caused certain scanners to be always
reported as busy
+ escl: Added support for Brother DCP-J772DW and Epson
ET-2750 scanners
+ escl: Marked the following scanners as supported in
documentation:
- Canon PIXMA G4511
- Canon PIXMA TR4550 Series
- Canon PIXMA TR4551 Series
- Epson ET-6100
+ escl: Implemented support for disabling PDF output on
scanners where it's broken (#510)
+ escl: Implemented support for Canon PIXME TR4520 and
TR7500 scanners
+ genesys: Improved scan quality on Canon LiDE 35/40/50/60
by using brighter LED illumination
+ genesys: Fixed control of contrast and brigthness on certain
scanners (#271)
+ genesys: Fixed crashes when handling slightly unexpected
conditions (#464)
+ genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
+ genesys: Fixed button support on HP ScanJet G4010
+ genesys: Fixed compilation on gcc-4.8
+ genesys: Fixed incorrect LED exposure calculation leading to
wrong color balance on certain resolutions on gl841 scanners
+ genesys: Improved gray scan quality on Canon LiDE 110, 120,
210, 220 (#106, #52)
+ genesys: Fixed issue of motor becoming stuck at certain
resolutions on Canon LiDE 50 and possibly other gl841
scanners (#357)
+ genesys: Fixed periodic black lines in gray scans on Canon
LiDE 80
+ genesys: Removed support for broken 75 and 100 dpi hardware
resolutions to fix preview scans (#383). These resolutions
did not have any benefit compared to next smallest 150 dpi
resolution
+ genesys: Add support for running in embedded environments
that don't support threads
+ genesys: Fixed gray scans to use white color for illumination
instead of red on Canon LiDE 35/40/50/60 and potentially
other gl841 scanners. Old behavior can be restored via the
color filter setting to select specific color component for
the gray scan
+ genesys: The genesys backend is now distributed under GPL v2
or later license. Previously there existed an exception that
allowed additional uses of the backend
+ gt68xx: Fixed several memory issues that can potentially lead
to crashes or increased memory use
+ hp4200: Fixed crash when using HP ScanJet 4200C (#454)
+ microtek: Fixed support for embedded platforms using uclibc
+ pieusb: Implemented support for Reflecta RPS 10M scanner
+ pieusb: Fixed support for automatically advancing slides on
DigitDia 4000
+ pixma: Fixed compliation with NDEBUG macro defined
+ pixma: Marked Canon PIXMA G4511 as supported in documentation
+ scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
as supported
* Frontends
+ Improved documentation of scanimage concerning options
provided by backends
+ scanimage: Improved help to specify which options are
advanced
+ scanimage: Implemented support for PDF output format
- Cleanup create_hpaio.desc_from_models.dat:
* Remove scanners unsupported by hplip (scan-type < 0)
* Simplify and significantly speed it up
OBS-URL: https://build.opensuse.org/request/show/949860
OBS-URL: https://build.opensuse.org/package/show/graphics/sane-backends?expand=0&rev=106
2022-01-31 14:34:31 +01:00
|
|
|
{ if [ "$TYPE" -gt "0" ]
|
|
|
|
then Normalize
|
|
|
|
UNIFIEDMODELS=$( echo $MODELS | tr ' ' '\n' | sort -u | tr '\n' ' ' )
|
|
|
|
ID=$(( "0x$ID" ))
|
2008-04-12 21:21:14 +02:00
|
|
|
for MODEL in $( echo $UNIFIEDMODELS )
|
|
|
|
do MODEL=$( echo $MODEL | sed -e "s/_/ /g" )
|
|
|
|
echo ":model \"$MODEL\""
|
Accepting request 949860 from home:StefanBruens:branches:graphics
- Upgraded to sane-backends version 1.1.1
* Backends
+ epson2: Fixed support for many scanners that don't support
focus command.
+ epson2: Improve reliability of long scans.
+ epsonds: Implemented support for the following Epson scanners:
- DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
- ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
ES-60WW, ES-65WR,
- ET-2700 Series, ET-2710 Series, ET-2810 Series,
ET-M2140 Series, ET-M3140 Series,
- EW-052A Series,
- FF-680W,
- L3150 Series, L3200 Series, L3210 Series, L3250 Series,
L4150 Series,
- M2140 Series, M3140 Series,
- RR-60, RR-600W, RR-70W,
- XP-2100 Series, XP-2150 Series
+ epson2: Marked XP-452 455 series as supported in
documentation
+ escl: Fixed scanning problems on certain scanners due to
incorrect URL being used (#479)
+ escl: Fixed support for different resolutions when using
JPEG format
+ escl: Fixed handling of ipp-usb redirects to localhost
which previously caused certain scanners to be always
reported as busy
+ escl: Added support for Brother DCP-J772DW and Epson
ET-2750 scanners
+ escl: Marked the following scanners as supported in
documentation:
- Canon PIXMA G4511
- Canon PIXMA TR4550 Series
- Canon PIXMA TR4551 Series
- Epson ET-6100
+ escl: Implemented support for disabling PDF output on
scanners where it's broken (#510)
+ escl: Implemented support for Canon PIXME TR4520 and
TR7500 scanners
+ genesys: Improved scan quality on Canon LiDE 35/40/50/60
by using brighter LED illumination
+ genesys: Fixed control of contrast and brigthness on certain
scanners (#271)
+ genesys: Fixed crashes when handling slightly unexpected
conditions (#464)
+ genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
+ genesys: Fixed button support on HP ScanJet G4010
+ genesys: Fixed compilation on gcc-4.8
+ genesys: Fixed incorrect LED exposure calculation leading to
wrong color balance on certain resolutions on gl841 scanners
+ genesys: Improved gray scan quality on Canon LiDE 110, 120,
210, 220 (#106, #52)
+ genesys: Fixed issue of motor becoming stuck at certain
resolutions on Canon LiDE 50 and possibly other gl841
scanners (#357)
+ genesys: Fixed periodic black lines in gray scans on Canon
LiDE 80
+ genesys: Removed support for broken 75 and 100 dpi hardware
resolutions to fix preview scans (#383). These resolutions
did not have any benefit compared to next smallest 150 dpi
resolution
+ genesys: Add support for running in embedded environments
that don't support threads
+ genesys: Fixed gray scans to use white color for illumination
instead of red on Canon LiDE 35/40/50/60 and potentially
other gl841 scanners. Old behavior can be restored via the
color filter setting to select specific color component for
the gray scan
+ genesys: The genesys backend is now distributed under GPL v2
or later license. Previously there existed an exception that
allowed additional uses of the backend
+ gt68xx: Fixed several memory issues that can potentially lead
to crashes or increased memory use
+ hp4200: Fixed crash when using HP ScanJet 4200C (#454)
+ microtek: Fixed support for embedded platforms using uclibc
+ pieusb: Implemented support for Reflecta RPS 10M scanner
+ pieusb: Fixed support for automatically advancing slides on
DigitDia 4000
+ pixma: Fixed compliation with NDEBUG macro defined
+ pixma: Marked Canon PIXMA G4511 as supported in documentation
+ scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
as supported
* Frontends
+ Improved documentation of scanimage concerning options
provided by backends
+ scanimage: Improved help to specify which options are
advanced
+ scanimage: Implemented support for PDF output format
- Cleanup create_hpaio.desc_from_models.dat:
* Remove scanners unsupported by hplip (scan-type < 0)
* Simplify and significantly speed it up
OBS-URL: https://build.opensuse.org/request/show/949860
OBS-URL: https://build.opensuse.org/package/show/graphics/sane-backends?expand=0&rev=106
2022-01-31 14:34:31 +01:00
|
|
|
if [ "$ID" -gt "0" ] ; then printf ":usbid \"0x03f0\" \"0x%.4x\"\n" $ID ; fi
|
2008-04-12 21:21:14 +02:00
|
|
|
echo ':status :good'
|
|
|
|
echo
|
|
|
|
done
|
|
|
|
fi
|
|
|
|
}
|
|
|
|
|
|
|
|
# Output model entries:
|
Accepting request 949860 from home:StefanBruens:branches:graphics
- Upgraded to sane-backends version 1.1.1
* Backends
+ epson2: Fixed support for many scanners that don't support
focus command.
+ epson2: Improve reliability of long scans.
+ epsonds: Implemented support for the following Epson scanners:
- DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
- ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
ES-60WW, ES-65WR,
- ET-2700 Series, ET-2710 Series, ET-2810 Series,
ET-M2140 Series, ET-M3140 Series,
- EW-052A Series,
- FF-680W,
- L3150 Series, L3200 Series, L3210 Series, L3250 Series,
L4150 Series,
- M2140 Series, M3140 Series,
- RR-60, RR-600W, RR-70W,
- XP-2100 Series, XP-2150 Series
+ epson2: Marked XP-452 455 series as supported in
documentation
+ escl: Fixed scanning problems on certain scanners due to
incorrect URL being used (#479)
+ escl: Fixed support for different resolutions when using
JPEG format
+ escl: Fixed handling of ipp-usb redirects to localhost
which previously caused certain scanners to be always
reported as busy
+ escl: Added support for Brother DCP-J772DW and Epson
ET-2750 scanners
+ escl: Marked the following scanners as supported in
documentation:
- Canon PIXMA G4511
- Canon PIXMA TR4550 Series
- Canon PIXMA TR4551 Series
- Epson ET-6100
+ escl: Implemented support for disabling PDF output on
scanners where it's broken (#510)
+ escl: Implemented support for Canon PIXME TR4520 and
TR7500 scanners
+ genesys: Improved scan quality on Canon LiDE 35/40/50/60
by using brighter LED illumination
+ genesys: Fixed control of contrast and brigthness on certain
scanners (#271)
+ genesys: Fixed crashes when handling slightly unexpected
conditions (#464)
+ genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
+ genesys: Fixed button support on HP ScanJet G4010
+ genesys: Fixed compilation on gcc-4.8
+ genesys: Fixed incorrect LED exposure calculation leading to
wrong color balance on certain resolutions on gl841 scanners
+ genesys: Improved gray scan quality on Canon LiDE 110, 120,
210, 220 (#106, #52)
+ genesys: Fixed issue of motor becoming stuck at certain
resolutions on Canon LiDE 50 and possibly other gl841
scanners (#357)
+ genesys: Fixed periodic black lines in gray scans on Canon
LiDE 80
+ genesys: Removed support for broken 75 and 100 dpi hardware
resolutions to fix preview scans (#383). These resolutions
did not have any benefit compared to next smallest 150 dpi
resolution
+ genesys: Add support for running in embedded environments
that don't support threads
+ genesys: Fixed gray scans to use white color for illumination
instead of red on Canon LiDE 35/40/50/60 and potentially
other gl841 scanners. Old behavior can be restored via the
color filter setting to select specific color component for
the gray scan
+ genesys: The genesys backend is now distributed under GPL v2
or later license. Previously there existed an exception that
allowed additional uses of the backend
+ gt68xx: Fixed several memory issues that can potentially lead
to crashes or increased memory use
+ hp4200: Fixed crash when using HP ScanJet 4200C (#454)
+ microtek: Fixed support for embedded platforms using uclibc
+ pieusb: Implemented support for Reflecta RPS 10M scanner
+ pieusb: Fixed support for automatically advancing slides on
DigitDia 4000
+ pixma: Fixed compliation with NDEBUG macro defined
+ pixma: Marked Canon PIXMA G4511 as supported in documentation
+ scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
as supported
* Frontends
+ Improved documentation of scanimage concerning options
provided by backends
+ scanimage: Improved help to specify which options are
advanced
+ scanimage: Implemented support for PDF output format
- Cleanup create_hpaio.desc_from_models.dat:
* Remove scanners unsupported by hplip (scan-type < 0)
* Simplify and significantly speed it up
OBS-URL: https://build.opensuse.org/request/show/949860
OBS-URL: https://build.opensuse.org/package/show/graphics/sane-backends?expand=0&rev=106
2022-01-31 14:34:31 +01:00
|
|
|
TYPE="0"
|
2008-04-12 21:21:14 +02:00
|
|
|
exec <$TMP_DATA
|
|
|
|
while read KEY VALUE
|
|
|
|
do case "$KEY" in
|
|
|
|
class) Output
|
Accepting request 949860 from home:StefanBruens:branches:graphics
- Upgraded to sane-backends version 1.1.1
* Backends
+ epson2: Fixed support for many scanners that don't support
focus command.
+ epson2: Improve reliability of long scans.
+ epsonds: Implemented support for the following Epson scanners:
- DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
- ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
ES-60WW, ES-65WR,
- ET-2700 Series, ET-2710 Series, ET-2810 Series,
ET-M2140 Series, ET-M3140 Series,
- EW-052A Series,
- FF-680W,
- L3150 Series, L3200 Series, L3210 Series, L3250 Series,
L4150 Series,
- M2140 Series, M3140 Series,
- RR-60, RR-600W, RR-70W,
- XP-2100 Series, XP-2150 Series
+ epson2: Marked XP-452 455 series as supported in
documentation
+ escl: Fixed scanning problems on certain scanners due to
incorrect URL being used (#479)
+ escl: Fixed support for different resolutions when using
JPEG format
+ escl: Fixed handling of ipp-usb redirects to localhost
which previously caused certain scanners to be always
reported as busy
+ escl: Added support for Brother DCP-J772DW and Epson
ET-2750 scanners
+ escl: Marked the following scanners as supported in
documentation:
- Canon PIXMA G4511
- Canon PIXMA TR4550 Series
- Canon PIXMA TR4551 Series
- Epson ET-6100
+ escl: Implemented support for disabling PDF output on
scanners where it's broken (#510)
+ escl: Implemented support for Canon PIXME TR4520 and
TR7500 scanners
+ genesys: Improved scan quality on Canon LiDE 35/40/50/60
by using brighter LED illumination
+ genesys: Fixed control of contrast and brigthness on certain
scanners (#271)
+ genesys: Fixed crashes when handling slightly unexpected
conditions (#464)
+ genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
+ genesys: Fixed button support on HP ScanJet G4010
+ genesys: Fixed compilation on gcc-4.8
+ genesys: Fixed incorrect LED exposure calculation leading to
wrong color balance on certain resolutions on gl841 scanners
+ genesys: Improved gray scan quality on Canon LiDE 110, 120,
210, 220 (#106, #52)
+ genesys: Fixed issue of motor becoming stuck at certain
resolutions on Canon LiDE 50 and possibly other gl841
scanners (#357)
+ genesys: Fixed periodic black lines in gray scans on Canon
LiDE 80
+ genesys: Removed support for broken 75 and 100 dpi hardware
resolutions to fix preview scans (#383). These resolutions
did not have any benefit compared to next smallest 150 dpi
resolution
+ genesys: Add support for running in embedded environments
that don't support threads
+ genesys: Fixed gray scans to use white color for illumination
instead of red on Canon LiDE 35/40/50/60 and potentially
other gl841 scanners. Old behavior can be restored via the
color filter setting to select specific color component for
the gray scan
+ genesys: The genesys backend is now distributed under GPL v2
or later license. Previously there existed an exception that
allowed additional uses of the backend
+ gt68xx: Fixed several memory issues that can potentially lead
to crashes or increased memory use
+ hp4200: Fixed crash when using HP ScanJet 4200C (#454)
+ microtek: Fixed support for embedded platforms using uclibc
+ pieusb: Implemented support for Reflecta RPS 10M scanner
+ pieusb: Fixed support for automatically advancing slides on
DigitDia 4000
+ pixma: Fixed compliation with NDEBUG macro defined
+ pixma: Marked Canon PIXMA G4511 as supported in documentation
+ scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
as supported
* Frontends
+ Improved documentation of scanimage concerning options
provided by backends
+ scanimage: Improved help to specify which options are
advanced
+ scanimage: Implemented support for PDF output format
- Cleanup create_hpaio.desc_from_models.dat:
* Remove scanners unsupported by hplip (scan-type < 0)
* Simplify and significantly speed it up
OBS-URL: https://build.opensuse.org/request/show/949860
OBS-URL: https://build.opensuse.org/package/show/graphics/sane-backends?expand=0&rev=106
2022-01-31 14:34:31 +01:00
|
|
|
ID="0"
|
2008-04-12 21:21:14 +02:00
|
|
|
TYPE="0"
|
Accepting request 949860 from home:StefanBruens:branches:graphics
- Upgraded to sane-backends version 1.1.1
* Backends
+ epson2: Fixed support for many scanners that don't support
focus command.
+ epson2: Improve reliability of long scans.
+ epsonds: Implemented support for the following Epson scanners:
- DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
- ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
ES-60WW, ES-65WR,
- ET-2700 Series, ET-2710 Series, ET-2810 Series,
ET-M2140 Series, ET-M3140 Series,
- EW-052A Series,
- FF-680W,
- L3150 Series, L3200 Series, L3210 Series, L3250 Series,
L4150 Series,
- M2140 Series, M3140 Series,
- RR-60, RR-600W, RR-70W,
- XP-2100 Series, XP-2150 Series
+ epson2: Marked XP-452 455 series as supported in
documentation
+ escl: Fixed scanning problems on certain scanners due to
incorrect URL being used (#479)
+ escl: Fixed support for different resolutions when using
JPEG format
+ escl: Fixed handling of ipp-usb redirects to localhost
which previously caused certain scanners to be always
reported as busy
+ escl: Added support for Brother DCP-J772DW and Epson
ET-2750 scanners
+ escl: Marked the following scanners as supported in
documentation:
- Canon PIXMA G4511
- Canon PIXMA TR4550 Series
- Canon PIXMA TR4551 Series
- Epson ET-6100
+ escl: Implemented support for disabling PDF output on
scanners where it's broken (#510)
+ escl: Implemented support for Canon PIXME TR4520 and
TR7500 scanners
+ genesys: Improved scan quality on Canon LiDE 35/40/50/60
by using brighter LED illumination
+ genesys: Fixed control of contrast and brigthness on certain
scanners (#271)
+ genesys: Fixed crashes when handling slightly unexpected
conditions (#464)
+ genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
+ genesys: Fixed button support on HP ScanJet G4010
+ genesys: Fixed compilation on gcc-4.8
+ genesys: Fixed incorrect LED exposure calculation leading to
wrong color balance on certain resolutions on gl841 scanners
+ genesys: Improved gray scan quality on Canon LiDE 110, 120,
210, 220 (#106, #52)
+ genesys: Fixed issue of motor becoming stuck at certain
resolutions on Canon LiDE 50 and possibly other gl841
scanners (#357)
+ genesys: Fixed periodic black lines in gray scans on Canon
LiDE 80
+ genesys: Removed support for broken 75 and 100 dpi hardware
resolutions to fix preview scans (#383). These resolutions
did not have any benefit compared to next smallest 150 dpi
resolution
+ genesys: Add support for running in embedded environments
that don't support threads
+ genesys: Fixed gray scans to use white color for illumination
instead of red on Canon LiDE 35/40/50/60 and potentially
other gl841 scanners. Old behavior can be restored via the
color filter setting to select specific color component for
the gray scan
+ genesys: The genesys backend is now distributed under GPL v2
or later license. Previously there existed an exception that
allowed additional uses of the backend
+ gt68xx: Fixed several memory issues that can potentially lead
to crashes or increased memory use
+ hp4200: Fixed crash when using HP ScanJet 4200C (#454)
+ microtek: Fixed support for embedded platforms using uclibc
+ pieusb: Implemented support for Reflecta RPS 10M scanner
+ pieusb: Fixed support for automatically advancing slides on
DigitDia 4000
+ pixma: Fixed compliation with NDEBUG macro defined
+ pixma: Marked Canon PIXMA G4511 as supported in documentation
+ scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
as supported
* Frontends
+ Improved documentation of scanimage concerning options
provided by backends
+ scanimage: Improved help to specify which options are
advanced
+ scanimage: Implemented support for PDF output format
- Cleanup create_hpaio.desc_from_models.dat:
* Remove scanners unsupported by hplip (scan-type < 0)
* Simplify and significantly speed it up
OBS-URL: https://build.opensuse.org/request/show/949860
OBS-URL: https://build.opensuse.org/package/show/graphics/sane-backends?expand=0&rev=106
2022-01-31 14:34:31 +01:00
|
|
|
MODELS="$VALUE" ;;
|
2008-04-12 21:21:14 +02:00
|
|
|
model*) MODELS=$( echo $MODELS $VALUE ) ;;
|
|
|
|
scan-type) TYPE="$VALUE" ;;
|
Accepting request 949860 from home:StefanBruens:branches:graphics
- Upgraded to sane-backends version 1.1.1
* Backends
+ epson2: Fixed support for many scanners that don't support
focus command.
+ epson2: Improve reliability of long scans.
+ epsonds: Implemented support for the following Epson scanners:
- DS-1610, DS-1630, DS-1660W, DS-310, DS-320, DS-360W, DS-410,
DS-530, DS-530II, DS-531, DS-535, DS-535H, DS-535II, DS-570W,
DS-570WII, DS-571W, DS-575W, DS-575WII, DS-70, DS-80W
- ES-200, ES-300W, ES-300WR, ES-400, ES-400II, ES-50, ES-500W,
ES-500WII, ES-500WR, ES-55R, ES-580W, ES-60W, ES-60WB,
ES-60WW, ES-65WR,
- ET-2700 Series, ET-2710 Series, ET-2810 Series,
ET-M2140 Series, ET-M3140 Series,
- EW-052A Series,
- FF-680W,
- L3150 Series, L3200 Series, L3210 Series, L3250 Series,
L4150 Series,
- M2140 Series, M3140 Series,
- RR-60, RR-600W, RR-70W,
- XP-2100 Series, XP-2150 Series
+ epson2: Marked XP-452 455 series as supported in
documentation
+ escl: Fixed scanning problems on certain scanners due to
incorrect URL being used (#479)
+ escl: Fixed support for different resolutions when using
JPEG format
+ escl: Fixed handling of ipp-usb redirects to localhost
which previously caused certain scanners to be always
reported as busy
+ escl: Added support for Brother DCP-J772DW and Epson
ET-2750 scanners
+ escl: Marked the following scanners as supported in
documentation:
- Canon PIXMA G4511
- Canon PIXMA TR4550 Series
- Canon PIXMA TR4551 Series
- Epson ET-6100
+ escl: Implemented support for disabling PDF output on
scanners where it's broken (#510)
+ escl: Implemented support for Canon PIXME TR4520 and
TR7500 scanners
+ genesys: Improved scan quality on Canon LiDE 35/40/50/60
by using brighter LED illumination
+ genesys: Fixed control of contrast and brigthness on certain
scanners (#271)
+ genesys: Fixed crashes when handling slightly unexpected
conditions (#464)
+ genesys: Fixed support for Plustek Opticfilm 7200 v2 scanner
+ genesys: Fixed button support on HP ScanJet G4010
+ genesys: Fixed compilation on gcc-4.8
+ genesys: Fixed incorrect LED exposure calculation leading to
wrong color balance on certain resolutions on gl841 scanners
+ genesys: Improved gray scan quality on Canon LiDE 110, 120,
210, 220 (#106, #52)
+ genesys: Fixed issue of motor becoming stuck at certain
resolutions on Canon LiDE 50 and possibly other gl841
scanners (#357)
+ genesys: Fixed periodic black lines in gray scans on Canon
LiDE 80
+ genesys: Removed support for broken 75 and 100 dpi hardware
resolutions to fix preview scans (#383). These resolutions
did not have any benefit compared to next smallest 150 dpi
resolution
+ genesys: Add support for running in embedded environments
that don't support threads
+ genesys: Fixed gray scans to use white color for illumination
instead of red on Canon LiDE 35/40/50/60 and potentially
other gl841 scanners. Old behavior can be restored via the
color filter setting to select specific color component for
the gray scan
+ genesys: The genesys backend is now distributed under GPL v2
or later license. Previously there existed an exception that
allowed additional uses of the backend
+ gt68xx: Fixed several memory issues that can potentially lead
to crashes or increased memory use
+ hp4200: Fixed crash when using HP ScanJet 4200C (#454)
+ microtek: Fixed support for embedded platforms using uclibc
+ pieusb: Implemented support for Reflecta RPS 10M scanner
+ pieusb: Fixed support for automatically advancing slides on
DigitDia 4000
+ pixma: Fixed compliation with NDEBUG macro defined
+ pixma: Marked Canon PIXMA G4511 as supported in documentation
+ scangearmp2: Mark GX6000, GX7000, TS5400 and MX455 series
as supported
* Frontends
+ Improved documentation of scanimage concerning options
provided by backends
+ scanimage: Improved help to specify which options are
advanced
+ scanimage: Implemented support for PDF output format
- Cleanup create_hpaio.desc_from_models.dat:
* Remove scanners unsupported by hplip (scan-type < 0)
* Simplify and significantly speed it up
OBS-URL: https://build.opensuse.org/request/show/949860
OBS-URL: https://build.opensuse.org/package/show/graphics/sane-backends?expand=0&rev=106
2022-01-31 14:34:31 +01:00
|
|
|
usb-pid) ID="$VALUE" ;;
|
2008-04-12 21:21:14 +02:00
|
|
|
*) echo "Ignoring key $KEY" 1>&2 ;;
|
|
|
|
esac
|
|
|
|
done
|
|
|
|
|
|
|
|
# Remove the temporary file
|
|
|
|
rm $TMP_DATA
|
|
|
|
exit 0
|
|
|
|
|