- Update mdadm to latest upstream state upto commit 582945c2d3bb. (jsc#PED-7542) 1) The testing changes are not included here. 2) Code clean up, and more helper routines added for Manage.c, Monitor.c, mdadm.c, ReadMe.c, super-intel.c, super0.c, super1.c, Create.c, Incremental.c and so on. 3) Man page update for mdadm.8.in. 4) Several memory leak and double free fixes. 5) Check /etc/initrd-release for whether systemd running on an initrd. - Manage: Block unsafe member failing 0062-Manage-Block-unsafe-member-failing.patch - Mdmonitor: Split alert() into separate functions 0063-Mdmonitor-Split-alert-into-separate-functions.patch - Monitor: block if monitor modes are combined. 0064-Monitor-block-if-monitor-modes-are-combined.patch - Update mdadm Monitor manual. 0065-Update-mdadm-Monitor-manual.patch - mdadm: create ident_init() 0066-mdadm-create-ident_init.patch - mdadm: Add option validation for --update-subarray 0067-mdadm-Add-option-validation-for-update-subarray.patch - Fix --update-subarray on active volume 0068-Fix-update-subarray-on-active-volume.patch - Add code specific update options to enum. 0069-Add-code-specific-update-options-to-enum.patch - super-ddf: Remove update_super_ddf. 0070-super-ddf-Remove-update_super_ddf.patch - super0: refactor the code for enum 0071-super0-refactor-the-code-for-enum.patch - super1: refactor the code for enum OBS-URL: https://build.opensuse.org/request/show/1137473 OBS-URL: https://build.opensuse.org/package/show/Base:System/mdadm?expand=0&rev=231
120 lines
3.3 KiB
Diff
120 lines
3.3 KiB
Diff
From 725e37cd14866906ba28c970394b9f7a4cd97413 Mon Sep 17 00:00:00 2001
|
|
From: Blazej Kucman <blazej.kucman@intel.com>
|
|
Date: Mon, 19 Dec 2022 11:21:58 +0100
|
|
Subject: [PATCH] Update mdadm Monitor manual.
|
|
|
|
- describe monitor work modes,
|
|
- clarify the turning off condition,
|
|
- describe the mdmonitor.service as a prefered management way.
|
|
|
|
Signed-off-by: Blazej Kucman <blazej.kucman@intel.com>
|
|
Signed-off-by: Jes Sorensen <jes@trained-monkey.org>
|
|
---
|
|
mdadm.8.in | 71 ++++++++++++++++++++++++++++++++++++++----------------
|
|
1 file changed, 50 insertions(+), 21 deletions(-)
|
|
|
|
diff --git a/mdadm.8.in b/mdadm.8.in
|
|
index 70c79d1..64f71ed 100644
|
|
--- a/mdadm.8.in
|
|
+++ b/mdadm.8.in
|
|
@@ -2548,13 +2548,33 @@ Usage:
|
|
.I options... devices...
|
|
|
|
.PP
|
|
-This usage causes
|
|
+Monitor option can work in two modes:
|
|
+.IP \(bu 4
|
|
+system wide mode, follow all md devices based on
|
|
+.B /proc/mdstat,
|
|
+.IP \(bu 4
|
|
+follow only specified MD devices in command line.
|
|
+.PP
|
|
+
|
|
+.B \-\-scan -
|
|
+indicates system wide mode. Option causes the
|
|
+.I monitor
|
|
+to track all md devices that appear in
|
|
+.B /proc/mdstat.
|
|
+If it is not set, then at least one
|
|
+.B device
|
|
+must be specified.
|
|
+
|
|
+Monitor usage causes
|
|
.I mdadm
|
|
to periodically poll a number of md arrays and to report on any events
|
|
noticed.
|
|
-.I mdadm
|
|
-will never exit once it decides that there are arrays to be checked,
|
|
-so it should normally be run in the background.
|
|
+
|
|
+In both modes,
|
|
+.I monitor
|
|
+will work as long as there is an active array with redundancy and it is defined to follow (for
|
|
+.B \-\-scan
|
|
+every array is followed).
|
|
|
|
As well as reporting events,
|
|
.I mdadm
|
|
@@ -2565,15 +2585,6 @@ or
|
|
.B domain
|
|
and if the destination array has a failed drive but no spares.
|
|
|
|
-If any devices are listed on the command line,
|
|
-.I mdadm
|
|
-will only monitor those devices, otherwise, all arrays listed in the
|
|
-configuration file will be monitored. Further, if
|
|
-.B \-\-scan
|
|
-is given, then any other md devices that appear in
|
|
-.B /proc/mdstat
|
|
-will also be monitored.
|
|
-
|
|
The result of monitoring the arrays is the generation of events.
|
|
These events are passed to a separate program (if specified) and may
|
|
be mailed to a given E-mail address.
|
|
@@ -2586,16 +2597,34 @@ device if relevant (such as a component device that has failed).
|
|
|
|
If
|
|
.B \-\-scan
|
|
-is given, then a program or an E-mail address must be specified on the
|
|
-command line or in the config file. If neither are available, then
|
|
+is given, then a
|
|
+.B program
|
|
+or an
|
|
+.B e-mail
|
|
+address must be specified on the
|
|
+command line or in the config file. If neither are available, then
|
|
.I mdadm
|
|
will not monitor anything.
|
|
-Without
|
|
-.B \-\-scan,
|
|
-.I mdadm
|
|
-will continue monitoring as long as something was found to monitor. If
|
|
-no program or email is given, then each event is reported to
|
|
-.BR stdout .
|
|
+For devices given directly in command line, without
|
|
+.B program
|
|
+or
|
|
+.B email
|
|
+specified, each event is reported to
|
|
+.BR stdout.
|
|
+
|
|
+Note: For systems where
|
|
+.If mdadm monitor
|
|
+is configured via systemd,
|
|
+.B mdmonitor(mdmonitor.service)
|
|
+should be configured. The service is designed to be primary solution for array monitoring,
|
|
+it is configured to work in system wide mode.
|
|
+It is automatically started and stopped according to current state and types of MD arrays in system.
|
|
+The service may require additional configuration, like
|
|
+.B e-mail
|
|
+or
|
|
+.B delay.
|
|
+That should be done in
|
|
+.B mdadm.conf.
|
|
|
|
The different events are:
|
|
|
|
--
|
|
2.35.3
|
|
|