#! /bin/bash
|
|
# Copyright (c) 2004 SUSE LINUX Products GmbH, Nuernberg, Germany
|
|
#
|
|
# Author: Johannes Meixner <http://www.suse.de/feedback>
|
|
#
|
|
# System startup script for setting scanner permissions in /dev/
|
|
#
|
|
### BEGIN INIT INFO
|
|
# Provides: sane-dev
|
|
# Required-Start: $remote_fs $syslog
|
|
# Should-Start: hal haldaemon
|
|
# Required-Stop: $remote_fs $syslog
|
|
# Default-Start: 3 5
|
|
# Default-Stop: 0 1 2 6
|
|
# Description: Setting scanner permissions in /dev/.
|
|
### END INIT INFO
|
|
|
|
# Shell functions sourced from /etc/rc.status:
|
|
# rc_check check and set local and overall rc status
|
|
# rc_status check and set local and overall rc status
|
|
# rc_status -v ditto but be verbose in local rc status
|
|
# rc_status -v -r ditto and clear the local rc status
|
|
# rc_failed set local and overall rc status to failed
|
|
# rc_failed <num> set local and overall rc status to <num><num>
|
|
# rc_reset clear local rc status (overall remains)
|
|
# rc_exit exit appropriate to overall rc status
|
|
. /etc/rc.status
|
|
|
|
# First reset status of this service
|
|
rc_reset
|
|
|
|
# Return values acc. to LSB for all commands but status:
|
|
# 0 - success
|
|
# 1 - generic or unspecified error
|
|
# 2 - invalid or excess argument(s)
|
|
# 3 - unimplemented feature (e.g. "reload")
|
|
# 4 - insufficient privilege
|
|
# 5 - program is not installed
|
|
# 6 - program is not configured
|
|
# 7 - program is not running
|
|
#
|
|
# Note that starting an already running service, stopping
|
|
# or restarting a not-running service as well as the restart
|
|
# with force-reload (in case signalling is not supported) are
|
|
# considered a success.
|
|
|
|
store_dir=/var/lib/sane
|
|
store_file=$store_dir/devices
|
|
maximum_wait=30
|
|
|
|
if [ "$1" != "status" -a "$( id -u )" != "0" ]
|
|
then echo "You must be root (except for \"$0 status\")."
|
|
rc_failed 4
|
|
rc_status
|
|
rc_exit
|
|
fi
|
|
|
|
case "$1" in
|
|
start)
|
|
if [ -x /usr/bin/scanimage ]
|
|
then echo -n "Searching for configured scanners in SANE."
|
|
[ -d $store_dir ] || mkdir -m 755 $store_dir
|
|
[ -f $store_file ] && mv $store_file ${store_file}.old
|
|
/usr/bin/scanimage -f '%d,' 1>${store_file}.raw 2>/dev/null &
|
|
scanimagePID=$!
|
|
for i in $( seq $maximum_wait )
|
|
do grep scanimage /proc/$scanimagePID/cmdline &>/dev/null || break
|
|
sleep 1
|
|
echo -n "."
|
|
done
|
|
if grep scanimage /proc/$scanimagePID/cmdline &>/dev/null
|
|
then echo -n " Aborted."
|
|
kill -9 $scanimagePID &>/dev/null
|
|
rc_failed 1
|
|
rc_status -v
|
|
rc_exit
|
|
fi
|
|
cat ${store_file}.raw | tr ',' '\n' | grep -v 'net:' | tr ':' '\n' | grep '^/dev/' | sort -u >$store_file
|
|
if [ -s $store_file ]
|
|
then echo -e "\nSetting scanner access mode to rw-rw-rw- for"
|
|
# to be safe only character device files are changed (e.g. harddisks are not changed)
|
|
for d in $( cat $store_file )
|
|
do [ -c $d ] && chmod 666 $d && echo -n "$d "
|
|
done
|
|
else echo -en "\nNo scanner device files found."
|
|
fi
|
|
else echo -n "Cannot execute /usr/bin/scanimage"
|
|
rc_failed 5
|
|
rc_status -v
|
|
rc_exit
|
|
fi
|
|
# Remember status and be verbose
|
|
rc_status -v
|
|
;;
|
|
stop)
|
|
if [ -s $store_file ]
|
|
then echo "Resetting scanner access mode to rw-r----- for"
|
|
# to be safe only character device files are changed (e.g. harddisks are not changed)
|
|
for d in $( cat $store_file )
|
|
do [ -c $d ] && chmod 640 $d && echo -n "$d "
|
|
done
|
|
else echo -n "There are no scanner device files in $store_file"
|
|
fi
|
|
# Remember status and be verbose
|
|
rc_status -v
|
|
;;
|
|
try-restart)
|
|
## Stop the service and if this succeeds (i.e. the
|
|
## service was running before), start it again.
|
|
## Note: try-restart is not (yet) part of LSB (as of 0.7.5)
|
|
$0 status >/dev/null && $0 restart
|
|
# Remember status and be quiet
|
|
rc_status
|
|
;;
|
|
restart)
|
|
## Stop the service and regardless of whether it was
|
|
## running or not, start it again.
|
|
$0 stop
|
|
$0 start
|
|
# Remember status and be quiet
|
|
rc_status
|
|
;;
|
|
force-reload)
|
|
## Signal the daemon to reload its config. Most daemons
|
|
## do this on signal 1 (SIGHUP).
|
|
## If it does not support it, restart.
|
|
rc_failed 3
|
|
rc_status -v
|
|
;;
|
|
reload)
|
|
## Like force-reload, but if daemon does not support
|
|
## signalling, do nothing (!)
|
|
# If it supports signalling:
|
|
rc_failed 3
|
|
;;
|
|
status)
|
|
if [ -s $store_file ]
|
|
then echo "Scanner access mode is"
|
|
# only character device files are of interest
|
|
for d in $( cat $store_file )
|
|
do [ -c $d ] && ls -l $d | cut -b 2-10 | tr -d '\n' && echo " for $d"
|
|
done
|
|
else echo "There are no scanner device files in $store_file"
|
|
fi
|
|
rc_status
|
|
;;
|
|
*)
|
|
echo "Usage: $0 {start|stop|status|try-restart|restart|force-reload|reload}"
|
|
exit 1
|
|
;;
|
|
esac
|
|