forked from pool/wireplumber
Antonio Larrosa
297b9fe9a2
- Better fix for (bsc#1223916) that basically turns the main profile into the (to be in 0.5.3) video-only profile unless wireplumber-audio is installed which now turns the main profile into exactly upstream's main profile. OBS-URL: https://build.opensuse.org/request/show/1172233 OBS-URL: https://build.opensuse.org/package/show/multimedia:libs/wireplumber?expand=0&rev=79
53 lines
2.1 KiB
Python
53 lines
2.1 KiB
Python
#!/usr/bin/python3
|
|
import hashlib
|
|
import sys
|
|
import re
|
|
|
|
def sha256_from_data(data):
|
|
hash_sha256 = hashlib.sha256()
|
|
hash_sha256.update(data)
|
|
return hash_sha256.hexdigest()
|
|
|
|
lines = open('wireplumber.conf', 'r', encoding='utf-8').readlines()
|
|
|
|
is_in_device_monitor = False
|
|
main_config_content = ''
|
|
device_monitors_content = ''
|
|
main_profile_contents = ''
|
|
|
|
for line in lines:
|
|
if re.match(' *## Device monitors$', line):
|
|
main_config_content += line
|
|
main_config_content += ' # Section moved to a device-monitors.conf file which is provided by the wireplumber-audio package\n\n'
|
|
is_in_device_monitor = True
|
|
continue
|
|
elif re.match(' *## ', line):
|
|
is_in_device_monitor = False
|
|
|
|
if is_in_device_monitor:
|
|
device_monitors_content += line
|
|
else:
|
|
# Fixes wireplumber running the main profile when not having audio support (bsc#1223916)
|
|
if line in [' hardware.audio = required\n', ' hardware.bluetooth = required\n']:
|
|
main_profile_contents += line
|
|
line = line.replace('required', 'disabled')
|
|
main_config_content += line
|
|
|
|
config_sha256 = sha256_from_data(device_monitors_content.encode('utf-8'))
|
|
verified_sha256 = 'bf33d018e5b924da71266636757fa264bc677b945c35e4dcd7f708da42731cc9'
|
|
if config_sha256 != verified_sha256:
|
|
print('The "Device monitors" section was modified, please verify that the contents are ok')
|
|
print('and if they are, modify the "verified_sha256" value in this script to')
|
|
print(f' {config_sha256}')
|
|
print('Current device monitors section is:')
|
|
print(device_monitors_content)
|
|
sys.exit(1)
|
|
|
|
device_monitors_content = 'wireplumber.components = [\n' + device_monitors_content + ']'
|
|
main_profile_contents = 'wireplumber.profiles = {\n main = {\n' + main_profile_contents + ' }\n}\n'
|
|
|
|
|
|
open('wireplumber.conf', 'w', encoding='utf-8').write(main_config_content)
|
|
open('wireplumber.conf.d/00-device-monitors.conf', 'w', encoding='utf-8').write(device_monitors_content)
|
|
open('wireplumber.conf.d/01-require-audio-in-main-profile.conf', 'w', encoding='utf-8').write(main_profile_contents)
|