- bnc#520234 - npiv does not work with XEN
Update block-npiv - bnc#496033 - Support for creating NPIV ports without starting vm block-npiv-common.sh block-npiv-vport Update block-npiv - bnc#500043 - Fix access to NPIV disk from HVM vm Update xen-qemu-iscsi-fix.patch OBS-URL: https://build.opensuse.org/package/show/Virtualization/xen?expand=0&rev=20
This commit is contained in:
committed by
Git OBS Bridge
parent
ca881773dc
commit
5ae0b92ca4
238
block-npiv-common.sh
Normal file
238
block-npiv-common.sh
Normal file
@@ -0,0 +1,238 @@
|
||||
|
||||
|
||||
# Look for the NPIV vport with the WWPN
|
||||
# $1 contains the WWPN (assumes it does not contain a leading "0x")
|
||||
find_vhost()
|
||||
{
|
||||
unset vhost
|
||||
|
||||
# look in upstream locations
|
||||
for fchost in /sys/class/fc_vports/* ; do
|
||||
if test -e $fchost/port_name ; then
|
||||
wwpn=`cat $fchost/port_name | sed -e s/^0x//`
|
||||
if test $wwpn = $1 ; then
|
||||
# Note: makes the assumption the vport will always have an scsi_host child
|
||||
vhost=`ls -d $fchost/device/host*`
|
||||
vhost=`basename $vhost`
|
||||
return
|
||||
fi
|
||||
fi
|
||||
done
|
||||
|
||||
# look in vendor-specific locations
|
||||
|
||||
# Emulex - just looks like another scsi_host - so look at fc_hosts...
|
||||
for fchost in /sys/class/fc_host/* ; do
|
||||
if test -e $fchost/port_name ; then
|
||||
wwpn=`cat $fchost/port_name | sed -e s/^0x//`
|
||||
if test $wwpn = $1 ; then
|
||||
# Note: makes the assumption the vport will always have an scsi_host child
|
||||
vhost=`basename $fchost`
|
||||
return
|
||||
fi
|
||||
fi
|
||||
done
|
||||
}
|
||||
|
||||
|
||||
# Create a NPIV vport on the fabric w/ FABRICNM, with WWPN,WWNN
|
||||
# $1 contains FABRICNM
|
||||
# $2 contains the VPORT WWPN
|
||||
# $3 contains the VPORT WWNN
|
||||
# (assumes no name contains a leading "0x")
|
||||
create_vport()
|
||||
{
|
||||
# find a base adapter with npiv support that is on the right fabric
|
||||
|
||||
# Look via upstream interfaces
|
||||
for fchost in /sys/class/fc_host/* ; do
|
||||
if test -e $fchost/vport_create ; then
|
||||
# is the link up, w/ NPIV support ?
|
||||
pstate=`cat $fchost/port_state`
|
||||
ptype=`cat $fchost/port_type | cut -c 1-5`
|
||||
fname=`cat $fchost/fabric_name | sed -e s/^0x//`
|
||||
if [ $pstate = "Online" -a $ptype = "NPort" -a $fname = $1 ] ; then
|
||||
vmax=`cat $fchost/max_npiv_vports`
|
||||
vinuse=`cat $fchost/npiv_vports_inuse`
|
||||
avail=`expr $vmax - $vinuse`
|
||||
if [ $avail -gt 0 ] ; then
|
||||
# create the vport
|
||||
echo $2":"$3 > $fchost/vport_create
|
||||
if [ $? -eq 0 ] ; then
|
||||
return 0
|
||||
fi
|
||||
# failed - so we'll just look for the next adapter
|
||||
fi
|
||||
fi
|
||||
fi
|
||||
done
|
||||
|
||||
# Look in vendor-specific locations
|
||||
|
||||
# Emulex: interfaces mirror upstream, but are under adapter scsi_host
|
||||
for shost in /sys/class/scsi_host/* ; do
|
||||
if [ -e $shost/vport_create ] ; then
|
||||
fchost=`ls -d $shost/device/fc_host*`
|
||||
# is the link up, w/ NPIV support ?
|
||||
pstate=`cat $fchost/port_state`
|
||||
ptype=`cat $fchost/port_type | cut -c 1-5`
|
||||
fname=`cat $fchost/fabric_name | sed -e s/^0x//`
|
||||
if [ $pstate = "Online" -a $ptype = "NPort" -a $fname = $1 ] ; then
|
||||
vmax=`cat $shost/max_npiv_vports`
|
||||
vinuse=`cat $shost/npiv_vports_inuse`
|
||||
avail=`expr $vmax - $vinuse`
|
||||
if [ $avail -gt 0 ] ; then
|
||||
# create the vport
|
||||
echo $2":"$3 > $shost/vport_create
|
||||
if [ $? -eq 0 ] ; then
|
||||
return 0
|
||||
fi
|
||||
# failed - so we'll just look for the next adapter
|
||||
fi
|
||||
fi
|
||||
fi
|
||||
done
|
||||
|
||||
return 1
|
||||
}
|
||||
|
||||
|
||||
# Look for the LUN on the indicated scsi_host (which is an NPIV vport)
|
||||
# $1 is the scsi_host name (normalized to simply the hostX name)
|
||||
# $2 is the WWPN of the tgt port the lun is on
|
||||
# Note: this implies we don't support a multipath'd lun, or we
|
||||
# are explicitly identifying a "path"
|
||||
# $3 is the LUN number of the scsi device
|
||||
find_sdev()
|
||||
{
|
||||
unset dev
|
||||
hostno=${1/*host/}
|
||||
for sdev in /sys/class/scsi_device/${hostno}:*:$3 ; do
|
||||
if test -e $sdev/device/../fc_trans*/target${hostno}*/port_name ; then
|
||||
tgtwwpn=`cat $sdev/device/../fc_trans*/target${hostno}*/port_name | sed -e s/^0x//`
|
||||
if test $tgtwwpn = $2 ; then
|
||||
if test -e $sdev/device/block* ; then
|
||||
dev=`ls $sdev/device/block*`
|
||||
dev=${dev##*/}
|
||||
return
|
||||
fi
|
||||
fi
|
||||
fi
|
||||
done
|
||||
}
|
||||
|
||||
|
||||
# Look for the NPIV vhost based on a scsi "sdX" name
|
||||
# $1 is the "sdX" name
|
||||
find_vhost_from_dev()
|
||||
{
|
||||
unset vhost
|
||||
hostno=`readlink /sys/block/$1/device`
|
||||
hostno=${hostno##*/}
|
||||
hostno=${hostno%%:*}
|
||||
if test -z "$hostno" ; then return; fi
|
||||
vhost="host"$hostno
|
||||
}
|
||||
|
||||
|
||||
# We're about to terminate a vhost based on a scsi device
|
||||
# Flush all nodes on that vhost as they are about to go away
|
||||
# $1 is the vhost
|
||||
flush_nodes_on_vhost()
|
||||
{
|
||||
if test ! -x /sbin/blockdev ; then return; fi
|
||||
hostno=${1/*host/}
|
||||
for sdev in /sys/class/scsi_device/${hostno}:* ; do
|
||||
if test -e $sdev/device/block* ; then
|
||||
dev=`ls $sdev/device/block*`
|
||||
dev="/dev/"$dev
|
||||
if test -n "$dev"; then
|
||||
blockdev --flushbufs $dev
|
||||
fi
|
||||
fi
|
||||
done
|
||||
}
|
||||
|
||||
|
||||
# Terminate a NPIV vhost
|
||||
# $1 is vhost
|
||||
delete_vhost()
|
||||
{
|
||||
# use upstream interface
|
||||
for vport in /sys/class/fc_vports/* ; do
|
||||
if test -e $vport/device/$1 ; then
|
||||
if test -e $vport/vport_delete ; then
|
||||
echo "1" > $vport/vport_delete
|
||||
if test $? -ne 0 ; then exit 6; fi
|
||||
sleep 4
|
||||
return
|
||||
fi
|
||||
fi
|
||||
done
|
||||
|
||||
# use vendor specific interface
|
||||
|
||||
# Emulex
|
||||
if test -e /sys/class/fc_host/$1/device/../scsi_host*/lpfc_drvr_version ; then
|
||||
shost=`ls -1d /sys/class/fc_host/$1/device/../scsi_host* | sed s/.*scsi_host://`
|
||||
vportwwpn=`cat /sys/class/fc_host/$1/port_name | sed s/^0x//`
|
||||
vportwwnn=`cat /sys/class/fc_host/$1/node_name | sed s/^0x//`
|
||||
echo "$vportwwpn:$vportwwnn" > /sys/class/scsi_host/$shost/vport_delete
|
||||
if test $? -ne 0 ; then exit 6; fi
|
||||
sleep 4
|
||||
return
|
||||
fi
|
||||
|
||||
# Qlogic
|
||||
if test -e /sys/class/fc_host/$1/device/../scsi_host*/driver_version ; then
|
||||
shost=`ls -1d /sys/class/fc_host/$1/device/../scsi_host* | sed s/.*scsi_host://`
|
||||
vportwwpn=`cat /sys/class/fc_host/$1/port_name | sed s/^0x//`
|
||||
vportwwnn=`cat /sys/class/fc_host/$1/node_name | sed s/^0x//`
|
||||
echo "$vportwwpn:$vportwwnn" > /sys/class/scsi_host/$shost/vport_delete
|
||||
if test $? -ne 0 ; then exit 6; fi
|
||||
sleep 4
|
||||
return
|
||||
fi
|
||||
|
||||
exit 6
|
||||
}
|
||||
|
||||
|
||||
vport_status()
|
||||
{
|
||||
# Look via upstream interfaces
|
||||
for fchost in /sys/class/fc_host/* ; do
|
||||
if test -e $fchost/vport_create ; then
|
||||
vport_status_display $fchost $fchost
|
||||
fi
|
||||
done
|
||||
|
||||
# Look in vendor-specific locations
|
||||
|
||||
# Emulex: interfaces mirror upstream, but are under adapter scsi_host
|
||||
for shost in /sys/class/scsi_host/* ; do
|
||||
if [ -e $shost/vport_create ] ; then
|
||||
fchost=`ls -d $shost/device/fc_host*`
|
||||
vport_status_display $fchost $shost
|
||||
fi
|
||||
done
|
||||
|
||||
return 0
|
||||
}
|
||||
|
||||
|
||||
vport_status_display()
|
||||
{
|
||||
echo
|
||||
echo "fc_host: " $2
|
||||
echo "port_state: " `cat $1/port_state`
|
||||
echo "port_type: " `cat $1/port_type`
|
||||
echo "fabric_name: " `cat $1/fabric_name`
|
||||
echo "max_npiv_vports: " `cat $2/max_npiv_vports`
|
||||
echo "npiv_vports_inuse: " `cat $2/npiv_vports_inuse`
|
||||
echo "modeldesc: " `cat $2/modeldesc`
|
||||
echo "speed: " `cat $1/speed`
|
||||
|
||||
return 0
|
||||
}
|
||||
|
Reference in New Issue
Block a user