- Update to Xen 4.1.2_rc2 c/s 23152 - bnc#716695 - domUs using tap devices will not start updated multi-xvdp.patch - Upstream patches from Jan 23803-intel-pmu-models.patch 23800-x86_64-guest-addr-range.patch 23795-intel-ich10-quirk.patch 23804-x86-IPI-counts.patch - bnc#706106 - Inconsistent reporting of VM names during migration xend-migration-domname-fix.patch - bnc#712823 - L3:Xen guest does not start reliable when rebooted xend-vcpu-affinity-fix.patch OBS-URL: https://build.opensuse.org/package/show/Virtualization/xen?expand=0&rev=143
43 lines
1.3 KiB
Diff
43 lines
1.3 KiB
Diff
References: fate#311487
|
|
|
|
Provide a modalias entry in xen-plaform-pci.ko to allow early autoloading in
|
|
initrd based on /sys/class/dmi/id/modalias
|
|
|
|
Signed-off-by: Olaf Hering <olaf@aepfle.de>
|
|
|
|
---
|
|
unmodified_drivers/linux-2.6/platform-pci/platform-pci.c | 13 +++++++++++++
|
|
1 file changed, 13 insertions(+)
|
|
|
|
Index: xen-4.1.2-testing/unmodified_drivers/linux-2.6/platform-pci/platform-pci.c
|
|
===================================================================
|
|
--- xen-4.1.2-testing.orig/unmodified_drivers/linux-2.6/platform-pci/platform-pci.c
|
|
+++ xen-4.1.2-testing/unmodified_drivers/linux-2.6/platform-pci/platform-pci.c
|
|
@@ -27,6 +27,7 @@
|
|
#include <linux/pci.h>
|
|
#include <linux/init.h>
|
|
#include <linux/version.h>
|
|
+#include <linux/dmi.h>
|
|
#include <linux/interrupt.h>
|
|
#include <linux/vmalloc.h>
|
|
#include <linux/mm.h>
|
|
@@ -480,6 +481,18 @@ static struct pci_device_id platform_pci
|
|
|
|
MODULE_DEVICE_TABLE(pci, platform_pci_tbl);
|
|
|
|
+static const struct dmi_system_id platform_dmi_tbl[] = {
|
|
+ {
|
|
+ .ident = "Xen PV-on-HVM",
|
|
+ .matches = {
|
|
+ DMI_MATCH(DMI_SYS_VENDOR, "Xen"),
|
|
+ DMI_MATCH(DMI_PRODUCT_NAME, "HVM domU"),
|
|
+ },
|
|
+ },
|
|
+ { },
|
|
+};
|
|
+MODULE_DEVICE_TABLE(dmi, platform_dmi_tbl);
|
|
+
|
|
static struct pci_driver platform_driver = {
|
|
name: DRV_NAME,
|
|
probe: platform_pci_init,
|